Background Catheter ablation is an effective treatment for premature ventricular contractions (PVCs). Mapping typically relies on bipolar (bip-EGMs) and unipolar electrograms (uni-EGMs). Recently, catheters equipped with microbipolar electrodes have become available. Objective This study aimed to investigate the value of microbipolar EGMs (micro-EGMs) in PVCs mapping. Methods We performed a multicenter retrospective study including patients who underwent successful outflow tract PVC ablation using QDOT catheters. 2 groups were identified based on the superficial or intramural origin of the PVC. EGMs—bip-, uni-, and micro-EGMs—were assessed at the successful ablation sites. The primary outcome was the ability of micro-EGM to discriminate between superficial and intramural PVCs. The secondary outcome was signal amplitude. Results Among 81 patients (mean age 54 ± 11 years; 59.3% male), 51 had superficial and 30 had intramural PVCs. In superficial PVC, micro-EGM preceded both uni-EGM and bip-EGM in 90% of cases. In particular, when the earliest bip-EGM preceded the earliest micro-EGM by >10 ms (Δbip-micro >10 ms), there was a high probability (sensitivity 0.94; specificity 0.75) of requiring ablation in both the right ventricular outflow tract and left ventricular outflow tract for successful PVC suppression. Micro-EGMs had higher initial deflection amplitude (1.5 vs 2.8 mV; P = .025). Conclusion Micro-EGMs allow more accurate PVC mapping, improving depth estimation. Micro-EGMs seem to be valuable for local activation time annotation with important implications on automated annotation algorithms within existing electroanatomic mapping systems.

The value of microelectrodes and microbipolar electrograms in premature ventricular complex mapping and ablation: The micro-PVC study / Bergonti, M., Szegedi, N., Compagnucci, P., Van Leuven, O., Özkartal, T., Caputo, M.L., Tanai, E., Saenen, J., Casella, M., Conte, G.. - In: HEART RHYTHM O2. - ISSN 2666-5018. - 7:6(2026), pp. 1157-1165. [10.1016/j.hroo.2026.03.007]

The value of microelectrodes and microbipolar electrograms in premature ventricular complex mapping and ablation: The micro-PVC study

Compagnucci, Paolo;Casella, Michela;
2026-01-01

Abstract

Background Catheter ablation is an effective treatment for premature ventricular contractions (PVCs). Mapping typically relies on bipolar (bip-EGMs) and unipolar electrograms (uni-EGMs). Recently, catheters equipped with microbipolar electrodes have become available. Objective This study aimed to investigate the value of microbipolar EGMs (micro-EGMs) in PVCs mapping. Methods We performed a multicenter retrospective study including patients who underwent successful outflow tract PVC ablation using QDOT catheters. 2 groups were identified based on the superficial or intramural origin of the PVC. EGMs—bip-, uni-, and micro-EGMs—were assessed at the successful ablation sites. The primary outcome was the ability of micro-EGM to discriminate between superficial and intramural PVCs. The secondary outcome was signal amplitude. Results Among 81 patients (mean age 54 ± 11 years; 59.3% male), 51 had superficial and 30 had intramural PVCs. In superficial PVC, micro-EGM preceded both uni-EGM and bip-EGM in 90% of cases. In particular, when the earliest bip-EGM preceded the earliest micro-EGM by >10 ms (Δbip-micro >10 ms), there was a high probability (sensitivity 0.94; specificity 0.75) of requiring ablation in both the right ventricular outflow tract and left ventricular outflow tract for successful PVC suppression. Micro-EGMs had higher initial deflection amplitude (1.5 vs 2.8 mV; P = .025). Conclusion Micro-EGMs allow more accurate PVC mapping, improving depth estimation. Micro-EGMs seem to be valuable for local activation time annotation with important implications on automated annotation algorithms within existing electroanatomic mapping systems.
2026
Ablation; Microbipolar; Microelectrodes; Premature ventricular contractions; QDOT; Ventricular
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/367418
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact