Paramagnetic oximeters are frequently used in clinical practice to measure and titrate the fraction of inspired oxygen (FiO2) administered to a hypoxic patient. Newborns are prone to several diseases leading to hypoxia but also to oxidative damage, therefore a precise measurement of administered oxygen is of paramount importance. In this study, we evaluated and compared the performance of four commonly used gas analyzers at a Neonatal Unit. A paramagnetic gas analyzer was considered the standard for reference. Gas mixing performed by blenders was also evaluated. We first assessed the stability and composition of O2 and medical air. A settling time study was conducted to estimate a steady-state. Results show how tested blenders underestimated the real measures when FiO2 was <50% and overestimated them when FiO2 ≥50%. In all the tested oximeters the FiO2 was underestimated by 1.18%, but the overall agreement with the gold standard was very good.

Uncertainty Estimation of Biomedical Oximeters: Proposal for an Experimental Test-Bench / Marchionni, P.; Nobile, S.; Carnielli, V. P.; Scalise, L.. - In: JOURNAL OF VERIFICATION, VALIDATION AND UNCERTAINTY QUANTIFICATION. - ISSN 2377-2158. - 6:3(2021). [10.1115/1.4050721]

Uncertainty Estimation of Biomedical Oximeters: Proposal for an Experimental Test-Bench

Carnielli V. P.;Scalise L.
2021-01-01

Abstract

Paramagnetic oximeters are frequently used in clinical practice to measure and titrate the fraction of inspired oxygen (FiO2) administered to a hypoxic patient. Newborns are prone to several diseases leading to hypoxia but also to oxidative damage, therefore a precise measurement of administered oxygen is of paramount importance. In this study, we evaluated and compared the performance of four commonly used gas analyzers at a Neonatal Unit. A paramagnetic gas analyzer was considered the standard for reference. Gas mixing performed by blenders was also evaluated. We first assessed the stability and composition of O2 and medical air. A settling time study was conducted to estimate a steady-state. Results show how tested blenders underestimated the real measures when FiO2 was <50% and overestimated them when FiO2 ≥50%. In all the tested oximeters the FiO2 was underestimated by 1.18%, but the overall agreement with the gold standard was very good.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/328160
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact