This paper discusses the electrical impedance behaviour, measured according to the Wenner’s method, of three different concrete mixes during accelerated degradation tests. Being a first attempt to move from laboratory to in-field applications targeted to long-term monitoring, the same electrode array configuration and set-up (AC current at 10 kHz) is used. Results show that electrical impedance decreases down to 24% in capillary water absorption tests, 77% and 86% in salt-spray chamber and wet/dry cycles with 3.5% NaCl solution, respectively. The two new low-clinker cements adopted seem to improve the measurement sensitivity towards contaminants ingress with respect to the commercial one (reference).

Performance of concretes manufactured with newly developed low-clinker cements exposed to water and chlorides: Characterization by means of electrical impedance measurements / Cosoli, G.; Mobili, A.; Giulietti, N.; Chiariotti, P.; Pandarese, G.; Tittarelli, F.; Bellezze, T.; Mikanovic, N.; Revel, G. M.. - In: CONSTRUCTION AND BUILDING MATERIALS. - ISSN 0950-0618. - 271:(2021), pp. 121546.1-121546.12. [10.1016/j.conbuildmat.2020.121546]

Performance of concretes manufactured with newly developed low-clinker cements exposed to water and chlorides: Characterization by means of electrical impedance measurements

G. Cosoli;A. Mobili;G. Pandarese;F. Tittarelli;T. Bellezze;G. M. Revel
2021-01-01

Abstract

This paper discusses the electrical impedance behaviour, measured according to the Wenner’s method, of three different concrete mixes during accelerated degradation tests. Being a first attempt to move from laboratory to in-field applications targeted to long-term monitoring, the same electrode array configuration and set-up (AC current at 10 kHz) is used. Results show that electrical impedance decreases down to 24% in capillary water absorption tests, 77% and 86% in salt-spray chamber and wet/dry cycles with 3.5% NaCl solution, respectively. The two new low-clinker cements adopted seem to improve the measurement sensitivity towards contaminants ingress with respect to the commercial one (reference).
2021
File in questo prodotto:
File Dimensione Formato  
2021 Performance of concretes manufactured with newly developed lowclinker cements exposed to water and chlorides.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 2.59 MB
Formato Adobe PDF
2.59 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Performance of concretes_sm_2021.pdf

accesso aperto

Tipologia: Documento in pre-print (manoscritto inviato all’editore precedente alla peer review)
Licenza d'uso: Creative commons
Dimensione 7.96 MB
Formato Adobe PDF
7.96 MB Adobe PDF Visualizza/Apri