In this paper, an electromagnetic sensing system for the measurement of the respiratory activity is presented. The aims are to demonstrate the feasibility of the proposed approach and in particular to evaluate the effect on the measured signal of the distance between the subject and the sensing apparatus. Moreover an electromagnetic model of the system, including the monitored subject, is proposed as a tool to solve the problem of selecting working parameters for system design. The sensing system is based on the measurement of the phase variation of the reflection coefficient caused by the respiratory activity. The phase signal compared with the thorax displacement measured by a reference instrument shows a high correlation (R =0.97) for different subject postures (sitting, standing and lying) and a reduction of the signal amplitude with the distance (-0.11 dB/cm) is reported. The numerical simulations performed on a wide band highlight the frequencies where the method exhibits the highest sensitivity to thorax movements. The sensitivity can be further improved by reducing the antenna beamwidth. Despite the signal amplitude reduction, the proposed system makes it possible to correctly operate at distances up to 2.5 m.

Wireless sensing for the respiratory activity of human beings: measurements and wide band numerical analysis / Scalise, Lorenzo; MARIANI PRIMIANI, Valter; Russo, Paola; DE LEO, Alfredo; Desar, Shahu; Cerri, Graziano. - In: INTERNATIONAL JOURNAL OF ANTENNAS AND PROPAGATION. - ISSN 1687-5869. - ELETTRONICO. - 2013:(2013). [10.1155/2013/396459]

Wireless sensing for the respiratory activity of human beings: measurements and wide band numerical analysis.

SCALISE, Lorenzo;MARIANI PRIMIANI, Valter;RUSSO, Paola;DE LEO, ALFREDO;CERRI, GRAZIANO
2013-01-01

Abstract

In this paper, an electromagnetic sensing system for the measurement of the respiratory activity is presented. The aims are to demonstrate the feasibility of the proposed approach and in particular to evaluate the effect on the measured signal of the distance between the subject and the sensing apparatus. Moreover an electromagnetic model of the system, including the monitored subject, is proposed as a tool to solve the problem of selecting working parameters for system design. The sensing system is based on the measurement of the phase variation of the reflection coefficient caused by the respiratory activity. The phase signal compared with the thorax displacement measured by a reference instrument shows a high correlation (R =0.97) for different subject postures (sitting, standing and lying) and a reduction of the signal amplitude with the distance (-0.11 dB/cm) is reported. The numerical simulations performed on a wide band highlight the frequencies where the method exhibits the highest sensitivity to thorax movements. The sensitivity can be further improved by reducing the antenna beamwidth. Despite the signal amplitude reduction, the proposed system makes it possible to correctly operate at distances up to 2.5 m.
2013
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/94263
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 14
social impact