BACKGROUND AND PURPOSE: The wide application of embolization in the treatment of aneurysms has created the need for an intraprocedural means to anticipate a poor outcome by monitoring hemodynamic changes in the brain. METHODS: Transcranial Doppler sonography was used to monitor now velocity in the middle cerebral artery (MCA) in 23 patients undergoing embolization with Guglielmi detachable coils (GDCs) of either incidental or symptomatic intracranial aneurysms, Sonographic values were recorded from the ipsilateral MCA at the beginning, middle, and end of the interventional procedure and 24 hours afterward. RESULTS: No complications occurred in 15 patients. In these cases, sonography showed an average decrease in MCA flow velocity of 2.7% after GDC application, returning to baseline at the end of treatment and then increasing by about 17% 24 hours later, In four patients with vasospasm on posttreatment angiograms, MCA flow velocity increased to values higher than 120 cm/s after GDC application, returning to baseline after 24 hours. In four patients with ischemic complications (two transient ischemic attacks, one stroke, one vascular death), MCA flow velocity decreased more than 30% and did not return to preoperative values within 24 hours. CONCLUSION: The application of transcranial Doppler sonographic monitoring during endovascular treatment may help to identify patients at risk for posttreatment cerebral ischemia.

Transcranial Doppler sonographic monitoring during cerebral aneurysm embolization: A preliminary report / G., Lagalla; Ceravolo, MARIA GABRIELLA; Provinciali, Leandro; M. A., Recchioni; A., Ducati; U., Pasquini; C., Piana; Salvolini, Ugo. - In: AJNR, AMERICAN JOURNAL OF NEURORADIOLOGY. - ISSN 0195-6108. - 19:(1998), pp. 1549-1553.

Transcranial Doppler sonographic monitoring during cerebral aneurysm embolization: A preliminary report

CERAVOLO, MARIA GABRIELLA;PROVINCIALI, LEANDRO;SALVOLINI, UGO
1998-01-01

Abstract

BACKGROUND AND PURPOSE: The wide application of embolization in the treatment of aneurysms has created the need for an intraprocedural means to anticipate a poor outcome by monitoring hemodynamic changes in the brain. METHODS: Transcranial Doppler sonography was used to monitor now velocity in the middle cerebral artery (MCA) in 23 patients undergoing embolization with Guglielmi detachable coils (GDCs) of either incidental or symptomatic intracranial aneurysms, Sonographic values were recorded from the ipsilateral MCA at the beginning, middle, and end of the interventional procedure and 24 hours afterward. RESULTS: No complications occurred in 15 patients. In these cases, sonography showed an average decrease in MCA flow velocity of 2.7% after GDC application, returning to baseline at the end of treatment and then increasing by about 17% 24 hours later, In four patients with vasospasm on posttreatment angiograms, MCA flow velocity increased to values higher than 120 cm/s after GDC application, returning to baseline after 24 hours. In four patients with ischemic complications (two transient ischemic attacks, one stroke, one vascular death), MCA flow velocity decreased more than 30% and did not return to preoperative values within 24 hours. CONCLUSION: The application of transcranial Doppler sonographic monitoring during endovascular treatment may help to identify patients at risk for posttreatment cerebral ischemia.
1998
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/71944
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 8
social impact