OBJECTIVES: To investigate the role of elastosonography to improve the reliability of the ultrasound in the measurement of the dermal thickness at finger level in systemic sclerosis (SSc). METHODS: Twenty-two patients with a diagnosis of SSc were consecutively recruited. In all patients at the second finger level of the dominant hand the dorsal aspect of proximal and middle phalanx was assessed in grey-scale and also using the elastosonography by an experienced musculoskeletal sonographer. The first step of the study was directed to explore the correlation between measurements of the dermal thickness using the grey-scale and elastosonography. Subsequently, the intra and the inter-reader reliability (between the sonographer who performed the ultrasound study and another sonographer) in the ultrasound measurements of the dermal thickness was assessed. Intra and inter-reader reliability was calculated using intra-class correlation coefficient (ICC) and illustrated by Bland-Altman plots. RESULTS: The ICC values were 0.904 and 0.979 for the intra-observer agreement, and 0.726 and 0.881 for the inter-observer agreement, using only the grey-scale and also the elastosonography, respectively. An excellent correlation was obtained between measurements in grey-scale and adopting the elastosonography by the experienced sonographer (rho=0.99), while the rho values between the two readers were 0.59 and 0.88, using the conventional technique and also the elastosonography, respectively. CONCLUSIONS: Elastosonography can improve the reliability of the US measurements of the dermal thickness at finger level in patients with SSc, helping for the identification of the interface dermis/hypodermis.

Reliability of ultrasound measurements of dermal tickness at digits in systemic sclerosis: role of elastosonography / Di Geso, L.; Filippucci, Emilio; Girolimetti, R.; Tardella, M.; Gutierrez, M.; DE ANGELIS, Rossella; Salaffi, Fausto; Grassi, Walter. - In: CLINICAL AND EXPERIMENTAL RHEUMATOLOGY. - ISSN 0392-856X. - 29 (6):(2011), pp. 926-932.

Reliability of ultrasound measurements of dermal tickness at digits in systemic sclerosis: role of elastosonography

FILIPPUCCI, Emilio;DE ANGELIS, Rossella;SALAFFI, FAUSTO;GRASSI, Walter
2011-01-01

Abstract

OBJECTIVES: To investigate the role of elastosonography to improve the reliability of the ultrasound in the measurement of the dermal thickness at finger level in systemic sclerosis (SSc). METHODS: Twenty-two patients with a diagnosis of SSc were consecutively recruited. In all patients at the second finger level of the dominant hand the dorsal aspect of proximal and middle phalanx was assessed in grey-scale and also using the elastosonography by an experienced musculoskeletal sonographer. The first step of the study was directed to explore the correlation between measurements of the dermal thickness using the grey-scale and elastosonography. Subsequently, the intra and the inter-reader reliability (between the sonographer who performed the ultrasound study and another sonographer) in the ultrasound measurements of the dermal thickness was assessed. Intra and inter-reader reliability was calculated using intra-class correlation coefficient (ICC) and illustrated by Bland-Altman plots. RESULTS: The ICC values were 0.904 and 0.979 for the intra-observer agreement, and 0.726 and 0.881 for the inter-observer agreement, using only the grey-scale and also the elastosonography, respectively. An excellent correlation was obtained between measurements in grey-scale and adopting the elastosonography by the experienced sonographer (rho=0.99), while the rho values between the two readers were 0.59 and 0.88, using the conventional technique and also the elastosonography, respectively. CONCLUSIONS: Elastosonography can improve the reliability of the US measurements of the dermal thickness at finger level in patients with SSc, helping for the identification of the interface dermis/hypodermis.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/63554
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 41
social impact