We have developed a blood velocimeter based on the principle of self-mixing in a semiconductor laser diode through an optical fiber. The intensity of the light is modulated by feedback from moving scattering particles that contain the Doppler-shift frequency. Upon feedback the characteristics of the laser diode change. The threshold current decreases, and an instable region may become present above the new threshold. The amplitude of the Doppler signal turns out to be related to the difference in intensity between situations with and without feedback. This amplitude is highest just above feedback. The suppression of reflection from the glass-fiber facets is of paramount importance in the obtaining of a higher signal-to-noise ratio. Using an optical stabilization of the feedback, we optimized the performance of the laser-fiber system and the Doppler modulation depth and clarified its behavior with a suitable physical model. We also investigated the effect of the finite coherence length of the laser. We tested the efficiency of the self-mixing velocimeter in vivo with the optical glass fiber inserted in the artery with endoscopic catheters, both in upstream and in downstream blood flow conditions. For the latter we used a special side-reflecting device solution for the fiber facet to allow downstream measurements.

Glass-fiber self-mixing intra-arterial laser Doppler velocimetry: Signal stability and feedback analysis / de Mul, F.; Scalise, Lorenzo; Petoukova, A.; van Herwijnen, M.; Moes, P.; Steenbergen, W.. - In: APPLIED OPTICS. - ISSN 0003-6935. - STAMPA. - 41:4(2002), pp. 658-667. [10.1364/AO.41.000658]

Glass-fiber self-mixing intra-arterial laser Doppler velocimetry: Signal stability and feedback analysis

SCALISE, Lorenzo;
2002-01-01

Abstract

We have developed a blood velocimeter based on the principle of self-mixing in a semiconductor laser diode through an optical fiber. The intensity of the light is modulated by feedback from moving scattering particles that contain the Doppler-shift frequency. Upon feedback the characteristics of the laser diode change. The threshold current decreases, and an instable region may become present above the new threshold. The amplitude of the Doppler signal turns out to be related to the difference in intensity between situations with and without feedback. This amplitude is highest just above feedback. The suppression of reflection from the glass-fiber facets is of paramount importance in the obtaining of a higher signal-to-noise ratio. Using an optical stabilization of the feedback, we optimized the performance of the laser-fiber system and the Doppler modulation depth and clarified its behavior with a suitable physical model. We also investigated the effect of the finite coherence length of the laser. We tested the efficiency of the self-mixing velocimeter in vivo with the optical glass fiber inserted in the artery with endoscopic catheters, both in upstream and in downstream blood flow conditions. For the latter we used a special side-reflecting device solution for the fiber facet to allow downstream measurements.
2002
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/59503
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 26
social impact