The aim was to investigate the effect of interferences surviving preprocessing (residual noise, baseline wanderings, respiration modulation, replaced beats, missed beats and T-waves misalignment) on automatic identification of T-wave alternans (TWA), an ECG index of risk for sudden cardiac death. The procedures denominated fast-Fourier-transform spectral method (FFTSM), complex-demodulation method (CDM), modified-moving-average method (MMAM), Laplacian-likelihood-ratio method (LLRM), and adaptive-match-filter method (AMFM) were applied to interferences-corrupted synthetic ECG tracings and Holter ECG recordings from control-healthy subjects (CH-group; n = 25) and acute-myocardial-infarction patients (AMI group; n = 25). The presence of interferences in simulated data caused detection of false-positive TWA by all techniques but the FFTSM and AMFM. Clinical applications evidenced a discrepancy in that the FFTSM and LLRM detected no more than one TWA case in each population, whereas the CDM, MMAM, and AMFM detected TWA in all CH-subjects and AMI-patients, with significantly lower TWA amplitude in the former group. Because the AMFM is not prone to false-positive TWA detections, the latter finding suggests TWA as a phenomenon having continuously changing amplitude from physiological to pathological conditions. Only occasional detection of TWA by the FFTSM and LLRM in clinics can be ascribed to their limited ability in identifying TWA in the presence of interferences surviving preprocessing.

Automatic microvolt T-wave alternans identification in relation to ECG interferences surviving preprocessing / Burattini, Laura; Bini, S.; Burattini, Roberto. - In: MEDICAL ENGINEERING & PHYSICS. - ISSN 1350-4533. - 33:(2011), pp. 17-30. [10.1016/j.medengphy.2010.08.014]

Automatic microvolt T-wave alternans identification in relation to ECG interferences surviving preprocessing

BURATTINI, LAURA;BURATTINI, ROBERTO
2011-01-01

Abstract

The aim was to investigate the effect of interferences surviving preprocessing (residual noise, baseline wanderings, respiration modulation, replaced beats, missed beats and T-waves misalignment) on automatic identification of T-wave alternans (TWA), an ECG index of risk for sudden cardiac death. The procedures denominated fast-Fourier-transform spectral method (FFTSM), complex-demodulation method (CDM), modified-moving-average method (MMAM), Laplacian-likelihood-ratio method (LLRM), and adaptive-match-filter method (AMFM) were applied to interferences-corrupted synthetic ECG tracings and Holter ECG recordings from control-healthy subjects (CH-group; n = 25) and acute-myocardial-infarction patients (AMI group; n = 25). The presence of interferences in simulated data caused detection of false-positive TWA by all techniques but the FFTSM and AMFM. Clinical applications evidenced a discrepancy in that the FFTSM and LLRM detected no more than one TWA case in each population, whereas the CDM, MMAM, and AMFM detected TWA in all CH-subjects and AMI-patients, with significantly lower TWA amplitude in the former group. Because the AMFM is not prone to false-positive TWA detections, the latter finding suggests TWA as a phenomenon having continuously changing amplitude from physiological to pathological conditions. Only occasional detection of TWA by the FFTSM and LLRM in clinics can be ascribed to their limited ability in identifying TWA in the presence of interferences surviving preprocessing.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/56745
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 32
social impact