Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
A systematic investigation of the properties of cerium fluoride monocrystals has been performed by the ''Crystal Clear'' collaboration in view of a possible use of such crystals for the construction of high precision electromagnetic calorimeters for the future generation of high luminosity accelerators. A large sample of different crystals grown by several producers has been studied. The spectroscopic characteristics, the transmission, luminescence aid excitation spectra and the decay time curves are analysed. The light yield of the different crystals is measured with photomultipliers and Si photodiodes and compared to reference standards like BGO and NaI(Tl). The radiation damage behaviour is then presented for gamma and neutron irradiations, at different doses and dose rates, including thermal and optical bleaching.
Further results on cerium fluoride crystals / Anderson, S., Auffray, E., Aziz, T., Baccaro, S., Banerjee, S., Bareyre, P., Barone, L.E., Borgia, B., Boutet, D., Burq, J.P., Chemarin, M., Chipaux, R., Dafinei, I., D'Atanasio, P., De Notaristefani, F., Dezillie, B., Dujardin, C., Dutta, S., Faure, J.L., Fay, J., et al.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 332:(1993), pp. 373-394. [10.1016/0168-9002(93)90296-T]
Further results on cerium fluoride crystals
Anderson S.;Auffray E.;Aziz T.;Baccaro S.;Banerjee S.;Bareyre P.;Barone L. E.;Borgia B.;Boutet D.;Burq J. P.;Chemarin M.;Chipaux R.;Dafinei I.;D'Atanasio P.;De Notaristefani F.;Dezillie B.;Dujardin C.;Dutta S.;Faure J. L.;Fay J.;Ferrère D.;FRANCESCANGELI, ORIANO;Fuchs B. A.;Ganguli S. N.;Gillespie G.;Goyot M.;Gupta S. K.;Gurtu A.;Heck J.;Hervé A.;Hillemanns H.;Holdener F.;Ille B.;Jönsson L.;Kierstead J.;Krenz W.;Kway W.;Le Goff J. M.;Lebeau M.;Lebrun P.;Lecoq P.;Lemoigne Y.;Loomis G.;Lubelsmeyer K.;Madjar N.;Majni G.;El Mamouni H.;Mangla S.;Mares J. A.;Martin J. P.;Mattioli M.;Mauger G. J.;Mazumdar K.;MENGUCCI, Paolo;Merlo J. P.;Moine B.;Nikl N.;Pansart J. P.;Pedrini C.;Poinsignon J.;Polak K.;Raghavan R.;Rebourgeard P.;RINALDI, DANIELE;Rosa J.;Rosowsky A.;Sahuc P.;Samsonov V.;Sarkar S.;Schegelski V.;Schmitz D.;Schneegans M.;Seliverstov D.;Stoll S.;Sudhakar K.;Svensson A.;Tonwar S. C.;Topa V.;Vialle J. P.;Vivargent M.;Wallraff W.;Weber M. J.;Winter N.;Woody C.;Wuest C. R.;Yanovski V.
1993-01-01
Abstract
A systematic investigation of the properties of cerium fluoride monocrystals has been performed by the ''Crystal Clear'' collaboration in view of a possible use of such crystals for the construction of high precision electromagnetic calorimeters for the future generation of high luminosity accelerators. A large sample of different crystals grown by several producers has been studied. The spectroscopic characteristics, the transmission, luminescence aid excitation spectra and the decay time curves are analysed. The light yield of the different crystals is measured with photomultipliers and Si photodiodes and compared to reference standards like BGO and NaI(Tl). The radiation damage behaviour is then presented for gamma and neutron irradiations, at different doses and dose rates, including thermal and optical bleaching.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/51282
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo
Citazioni
ND
48
39
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.