Purpose: To evaluate microtensile bond strength and interfacial nanoleakage expression of adhesive interfaces created by XP-Bond on human deproteinized dentin immediately after bonding and after 6 months of artificial aging.Materials and Methods: Noncarious human molars were selected, middle/deep dentin substrates were exposed, and either assigned to group 1 (XP-Bond applied on collagen-depleted dentin) or to group 2 (XP-Bond applied in accordance with manufacturers' instructions). In group 1, the etched dentin surface was treated with 10% NaOCl for 60 s to remove the exposed demineralized organic matrix before XP-Bond application. Composite/dentin beams were obtained in accordance with the microtensile nontrimming technique and either pulled to failure after 24 h or after 6 months' artificial aging. Data were analyzed with two-way ANOVA and Tukey's post-hoc test (p < 0.05). Interfacial nanoleakage evaluation was performed on additional adhesive interfaces to quantify the amount of silver tracer along the interface.Results: The use of NaOCl before XP-Bond application (group 1: 18.9 +/- 5.8 MPa) reduced immediate bond strength by 62% compared to controls (group 2: 49.9 +/- 10.3 MPa; p < 0.5). After 6 months of artificial aging, the bond strength of groups 1 and 2 significantly decreased to 10.1 +/- 2.7 MPa and 35.2 +/- 8.7 MPa, resp (p < 0.05). Interfacial nanoleakage expression along XP-Bond adhesive interfaces was increased either by sodium hypochlorite or by artificial aging.Conclusion: The role of Collagen fibrils is pivotal for the bonding of XP-Bond to dentin, as decreased immediate bond strength and reduced bond stability over time was found on collagen-depleted dentin.

Adhesion of a two-step etch-and-rinse adhesive on collagen-depleted dentin / Saboia, Vpa; Nato, F; Mazzoni, A; Orsini, Giovanna; Putignano, Angelo; Giannini, M; Breschi, L.. - In: JOURNAL OF ADHESIVE DENTISTRY. - ISSN 1461-5185. - STAMPA. - 10:(2008), pp. 419-422.

Adhesion of a two-step etch-and-rinse adhesive on collagen-depleted dentin.

ORSINI, Giovanna;PUTIGNANO, Angelo;
2008-01-01

Abstract

Purpose: To evaluate microtensile bond strength and interfacial nanoleakage expression of adhesive interfaces created by XP-Bond on human deproteinized dentin immediately after bonding and after 6 months of artificial aging.Materials and Methods: Noncarious human molars were selected, middle/deep dentin substrates were exposed, and either assigned to group 1 (XP-Bond applied on collagen-depleted dentin) or to group 2 (XP-Bond applied in accordance with manufacturers' instructions). In group 1, the etched dentin surface was treated with 10% NaOCl for 60 s to remove the exposed demineralized organic matrix before XP-Bond application. Composite/dentin beams were obtained in accordance with the microtensile nontrimming technique and either pulled to failure after 24 h or after 6 months' artificial aging. Data were analyzed with two-way ANOVA and Tukey's post-hoc test (p < 0.05). Interfacial nanoleakage evaluation was performed on additional adhesive interfaces to quantify the amount of silver tracer along the interface.Results: The use of NaOCl before XP-Bond application (group 1: 18.9 +/- 5.8 MPa) reduced immediate bond strength by 62% compared to controls (group 2: 49.9 +/- 10.3 MPa; p < 0.5). After 6 months of artificial aging, the bond strength of groups 1 and 2 significantly decreased to 10.1 +/- 2.7 MPa and 35.2 +/- 8.7 MPa, resp (p < 0.05). Interfacial nanoleakage expression along XP-Bond adhesive interfaces was increased either by sodium hypochlorite or by artificial aging.Conclusion: The role of Collagen fibrils is pivotal for the bonding of XP-Bond to dentin, as decreased immediate bond strength and reduced bond stability over time was found on collagen-depleted dentin.
2008
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/38255
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 74
social impact