Objective Operator technical skill is recognised as a critical determinant of surgical outcomes. However, no equivalent recognition for quality of endoscope tip manipulation (tip-control) exists. We aimed to create an ex-vivo snare tip soft coagulation (STSC) model to objectively quantify endoscopist tip-control. Method This prospective interventional study was conducted at Ghent University Hospital. Participants applied STSC to a training model simulating four endoscopic mucosal resection (EMR) defects on a slice of ham. Accuracy (correct/total-hits) and speed (correct-hits/s) were assessed from a video by a single-blinded rater using a web-based scoring system. Results 22 endoscopists participated. Interventional endoscopists demonstrated significantly higher accuracy (87.0%) and speed (0.184 correct-hits/s) compared with trainees (74.5%, 0.106 correct-hits/s; both p<0.001) and non-interventional consultants (77%, 0.141 correct-hits/s; p<0.001). The tip-control of trainees and non-interventional consultants was not significantly different. Endoscopists having performed ≥1000 colonoscopies, performing SMSA-4 polypectomies or ≥50 EMRs/year showed superior tip-control. Endoscopists with >5 years of endoscopic experience did not have better tip-control (accuracy 88.0%(p=0.07), speed 0.132 hits/s (p=0.36)) when compared with those with ≤4 years of experience. Conclusion This inexpensive ex vivo STSC simulation model effectively quantified endoscopic tip-control, correlating with endoscopist expertise and clinical profiles. The model could support the shift towards competency-based education, potentially improving patient outcomes. Trial registration number NCT05660317.
Endoscopic tip-control measured by a snare tip soft coagulation training model correlates with endoscopist profile and therapeutic expertise (The HAM Study) / Debels, L.K., Sorge, A., Argenziano, M.E., Lala, V., Montori, M., Poortmans, P.J., Smeets, S., Tornai, T., Van Vlierberghe, H., Desomer, L., Valori, R., Anderson, J., Tate, D.J.. - In: FRONTLINE GASTROENTEROLOGY. - ISSN 2041-4137. - 16:6(2025), pp. 445-451. [10.1136/flgastro-2024-103044]
Endoscopic tip-control measured by a snare tip soft coagulation training model correlates with endoscopist profile and therapeutic expertise (The HAM Study)
Argenziano M. E.;Montori M.;Valori R.;
2025-01-01
Abstract
Objective Operator technical skill is recognised as a critical determinant of surgical outcomes. However, no equivalent recognition for quality of endoscope tip manipulation (tip-control) exists. We aimed to create an ex-vivo snare tip soft coagulation (STSC) model to objectively quantify endoscopist tip-control. Method This prospective interventional study was conducted at Ghent University Hospital. Participants applied STSC to a training model simulating four endoscopic mucosal resection (EMR) defects on a slice of ham. Accuracy (correct/total-hits) and speed (correct-hits/s) were assessed from a video by a single-blinded rater using a web-based scoring system. Results 22 endoscopists participated. Interventional endoscopists demonstrated significantly higher accuracy (87.0%) and speed (0.184 correct-hits/s) compared with trainees (74.5%, 0.106 correct-hits/s; both p<0.001) and non-interventional consultants (77%, 0.141 correct-hits/s; p<0.001). The tip-control of trainees and non-interventional consultants was not significantly different. Endoscopists having performed ≥1000 colonoscopies, performing SMSA-4 polypectomies or ≥50 EMRs/year showed superior tip-control. Endoscopists with >5 years of endoscopic experience did not have better tip-control (accuracy 88.0%(p=0.07), speed 0.132 hits/s (p=0.36)) when compared with those with ≤4 years of experience. Conclusion This inexpensive ex vivo STSC simulation model effectively quantified endoscopic tip-control, correlating with endoscopist expertise and clinical profiles. The model could support the shift towards competency-based education, potentially improving patient outcomes. Trial registration number NCT05660317.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.