Abstract – Introduction: The aim of this study was to compare the emulsification rates, intraocular pressure (IOP) changes, and retinal hyperreflective foci (HRF) between low-viscosity (1, 000 cS) and high-viscosity (5, 000 cS) silicone oils (SOs) used as tamponade agents following 25-gauge pars plana vitrectomy (PPV) in cases of naïve macula-off rhegmatogenous retinal detachment using an artificial intelligence (AI)-based quantification approach. Methods: This retrospective study was conducted in eyes treated with PPV and SO tamponade. The clinical parameters that were assessed included best-corrected visual acuity (BCVA), IOP, the presence of emulsification in the iridocorneal angle – in the anterior or posterior chambers, and structural retinal biomarkers such as intraretinal fluid, subretinal fluid, and HRF detected and quantified through an AI-based analysis of spectral-domain optical coherence tomography (OCT) images. Results: Twenty-five eyes were enrolled (12 with 1, 000-cS SO and 13 with 5, 000-cS SO endotamponades) for this study. No statistically significant differences in BCVA or anatomical outcomes between the two groups were found. However, SO emulsification occurred more often in the 1, 000-cS group (66%) compared to the 5, 000-cS group (7%) (p = 0.0036). Elevated IOP was more frequent in the 1, 000-cS group (8 vs. 4 cases; p = 0.03), and HRF count was significantly higher in eyes with 1, 000-cS oil (p = 0.04). Conclusion: High-viscosity SO demonstrated a lower emulsification rate and reduced inflammatory response compared to low-viscosity SO, with no compromise in visual outcomes. AI-assisted OCT analysis enabled an accurate, automated detection of HRF, supporting its utility in monitoring SO-related complications.

Comparative Evaluation of High- versus Low-Viscosity Silicone Oil in Macula-Off Retinal Detachment: Emulsification, Inflammation, and AI-Assisted Biomarker Detection / Mariotti, C., Iorio, S., Gregori, G., Nacciarriti, E., Mangoni, L., Rizzo, C., Lupidi, M.. - In: OPHTHALMOLOGICA. - ISSN 0030-3755. - 249:3(2026), pp. 1-8. [10.1159/000551074]

Comparative Evaluation of High- versus Low-Viscosity Silicone Oil in Macula-Off Retinal Detachment: Emulsification, Inflammation, and AI-Assisted Biomarker Detection

Mariotti C.;Iorio S.;Gregori G.;Nacciarriti E.;Lupidi M.
2026-01-01

Abstract

Abstract – Introduction: The aim of this study was to compare the emulsification rates, intraocular pressure (IOP) changes, and retinal hyperreflective foci (HRF) between low-viscosity (1, 000 cS) and high-viscosity (5, 000 cS) silicone oils (SOs) used as tamponade agents following 25-gauge pars plana vitrectomy (PPV) in cases of naïve macula-off rhegmatogenous retinal detachment using an artificial intelligence (AI)-based quantification approach. Methods: This retrospective study was conducted in eyes treated with PPV and SO tamponade. The clinical parameters that were assessed included best-corrected visual acuity (BCVA), IOP, the presence of emulsification in the iridocorneal angle – in the anterior or posterior chambers, and structural retinal biomarkers such as intraretinal fluid, subretinal fluid, and HRF detected and quantified through an AI-based analysis of spectral-domain optical coherence tomography (OCT) images. Results: Twenty-five eyes were enrolled (12 with 1, 000-cS SO and 13 with 5, 000-cS SO endotamponades) for this study. No statistically significant differences in BCVA or anatomical outcomes between the two groups were found. However, SO emulsification occurred more often in the 1, 000-cS group (66%) compared to the 5, 000-cS group (7%) (p = 0.0036). Elevated IOP was more frequent in the 1, 000-cS group (8 vs. 4 cases; p = 0.03), and HRF count was significantly higher in eyes with 1, 000-cS oil (p = 0.04). Conclusion: High-viscosity SO demonstrated a lower emulsification rate and reduced inflammatory response compared to low-viscosity SO, with no compromise in visual outcomes. AI-assisted OCT analysis enabled an accurate, automated detection of HRF, supporting its utility in monitoring SO-related complications.
2026
Artificial intelligence; Emulsification; Hyperreflective foci; Retinal detachment; Silicone oil
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/367072
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact