Background: During the COVID-19 pandemic, rapid and reliable diagnostic tools are needed for detecting SARS-CoV-2 infection in urgent cases at admission to the hospital. We aimed to assess the performances of the rapid molecular VitaPCR™ test (Menarini Diagnostics) in a sample of older adults admitted to the Emergency Department of two Italian hospitals (2) Methods: The comparison between the rapid VitaPCR™ and the RT-PCR was performed in 1695 samples. Two naso-pharyngeal swab samplings from each individual were obtained and processed using the VitaPCR™ and the RT-PCR for the detection of SARS-CoV-2 (3) Results: VitaPCR™ exhibited good precision (<3% CV) and an almost perfect overall agreement (Cohen's K = 0.90) with the RT-PCR. The limit of detection of the VitaPCR™ was 4.1 copies/µL. Compared to the RT-PCR, the sensitivity, the specificity, and the positive and negative predictive values of VitaPCR™ were 83.4%, 99.9%, 99.2% and 98.3%, respectively (4) Conclusions: The VitaPCR™ showed similar sensitivity and specificity to other molecular-based rapid tests. This study suggests that the VitaPCR™ can allow the rapid management of patients within the Emergency Department. Nevertheless, it is advisable to obtain a negative result by a RT-PCR assay before admitting a patient to a regular ward.

Sensibility and Specificity of the VitaPCR™ SARS-CoV-2 Assay for the Rapid Diagnosis of COVID-19 in Older Adults in the Emergency Department / Piacenza, F., Cherubini, A., Galeazzi, R., Cardelli, M., Giacconi, R., Pierpaoli, E., Marchegiani, F., Marcheselli, F., Recchioni, R., Casoli, T., Farnocchia, E., Bartozzi, B., Giorgetti, B., Stripoli, P., Bonfigli, A.R., Fedecostante, M., Salvi, F., Pansoni, A., Provinciali, M., Lattanzio, F.. - In: VIRUSES. - ISSN 1999-4915. - 15:1(2023). [10.3390/v15010189]

Sensibility and Specificity of the VitaPCR™ SARS-CoV-2 Assay for the Rapid Diagnosis of COVID-19 in Older Adults in the Emergency Department

Cherubini A.
Co-primo
;
2023-01-01

Abstract

Background: During the COVID-19 pandemic, rapid and reliable diagnostic tools are needed for detecting SARS-CoV-2 infection in urgent cases at admission to the hospital. We aimed to assess the performances of the rapid molecular VitaPCR™ test (Menarini Diagnostics) in a sample of older adults admitted to the Emergency Department of two Italian hospitals (2) Methods: The comparison between the rapid VitaPCR™ and the RT-PCR was performed in 1695 samples. Two naso-pharyngeal swab samplings from each individual were obtained and processed using the VitaPCR™ and the RT-PCR for the detection of SARS-CoV-2 (3) Results: VitaPCR™ exhibited good precision (<3% CV) and an almost perfect overall agreement (Cohen's K = 0.90) with the RT-PCR. The limit of detection of the VitaPCR™ was 4.1 copies/µL. Compared to the RT-PCR, the sensitivity, the specificity, and the positive and negative predictive values of VitaPCR™ were 83.4%, 99.9%, 99.2% and 98.3%, respectively (4) Conclusions: The VitaPCR™ showed similar sensitivity and specificity to other molecular-based rapid tests. This study suggests that the VitaPCR™ can allow the rapid management of patients within the Emergency Department. Nevertheless, it is advisable to obtain a negative result by a RT-PCR assay before admitting a patient to a regular ward.
2023
rapid diagnostic test; SARS-CoV-2; sensitivity; specificity; VitaPCR
File in questo prodotto:
File Dimensione Formato  
Piacenza 2023 viruses-15-00189-v2-1.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Creative commons
Dimensione 3.35 MB
Formato Adobe PDF
3.35 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/363872
Citazioni