Heating, Ventilation, and Air Conditioning systems are essential for maintaining thermal comfort and Indoor Air Quality (IAQ) while influencing building energy consumption. This paper presents a simulation-based study of a residential heating system addressing temperature and IAQ control. CO2 is considered as IAQ parameter. The model is developed in MATLAB/Simulink using Simscape libraries to capture the coupled thermal and moisture dynamics of the indoor environment. Occupancy acts as a disturbance by affecting heat, moisture, and CO2 emissions, affecting indoor conditions. Natural ventilation (windows opening) is activated based on suitable CO2 thresholds. In addition, two room temperature control strategies are compared: a traditional bang-bang control strategy and a PI controller. Suitable scenarios are exploited to provide a qualitative and quantitative analysis.

Indoor Temperature and IAQ Control in an Office / Ali, M.F., Benotsmane, R., Pepe, C., Trohak, A., Zanoli, S.M.. - (2026), pp. 19-24. (27th International Carpathian Control Conference, ICCC 2026 Szilvasvarad 1 - 3 June 2026) [10.1109/ICCC71363.2026.11593321].

Indoor Temperature and IAQ Control in an Office

Ali M. F.
Primo
;
Pepe C.;Zanoli S. M.
Ultimo
2026-01-01

Abstract

Heating, Ventilation, and Air Conditioning systems are essential for maintaining thermal comfort and Indoor Air Quality (IAQ) while influencing building energy consumption. This paper presents a simulation-based study of a residential heating system addressing temperature and IAQ control. CO2 is considered as IAQ parameter. The model is developed in MATLAB/Simulink using Simscape libraries to capture the coupled thermal and moisture dynamics of the indoor environment. Occupancy acts as a disturbance by affecting heat, moisture, and CO2 emissions, affecting indoor conditions. Natural ventilation (windows opening) is activated based on suitable CO2 thresholds. In addition, two room temperature control strategies are compared: a traditional bang-bang control strategy and a PI controller. Suitable scenarios are exploited to provide a qualitative and quantitative analysis.
2026
9798319533203
File in questo prodotto:
File Dimensione Formato  
Ali_Indoor-Temperature-IAQ-Control-Office_2026.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 1.9 MB
Formato Adobe PDF
1.9 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/362036
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact