This paper proposes an analysis of the performance associated to heating technologies. In particular, heat pumps are considered together with different configurations characterized by the presence or not of a buffer and by various heating systems, i.e., radiators and underfloor heating. In addition, different sizing of the various elements is considered. The inclusion of a buffer in the design of a heating plant represents a critical choice due to its purchase and installation costs and to the space required for its installation. A focus on defrost cycles of the heat pump is presented in terms of observed failures. Different scenarios are taken into account in order to provide a thorough analysis in terms of significant key performance indicators, e.g., the number of defrost failures. A tailored simulator based on a mathematical model is used to perform the simulations in the different scenarios designed and to analyse the data obtained; Dymola and MATLAB/Simulink environments are exploited.
PERFORMANCE ASSESSMENT OF RESIDENTIAL HEAT PUMP SYSTEMS WITH AND WITHOUT BUFFER TANK INTEGRATION: A SIMULATION-BASED STUDY / Ali, M. F.; Perticaroli, F.; Marra, L.; Pepe, C.; Zanoli, S. M.. - 265:(2025), pp. 57-70. [10.2495/ESUS250051]
PERFORMANCE ASSESSMENT OF RESIDENTIAL HEAT PUMP SYSTEMS WITH AND WITHOUT BUFFER TANK INTEGRATION: A SIMULATION-BASED STUDY
Ali M. F.;Pepe C.;Zanoli S. M.
2025-01-01
Abstract
This paper proposes an analysis of the performance associated to heating technologies. In particular, heat pumps are considered together with different configurations characterized by the presence or not of a buffer and by various heating systems, i.e., radiators and underfloor heating. In addition, different sizing of the various elements is considered. The inclusion of a buffer in the design of a heating plant represents a critical choice due to its purchase and installation costs and to the space required for its installation. A focus on defrost cycles of the heat pump is presented in terms of observed failures. Different scenarios are taken into account in order to provide a thorough analysis in terms of significant key performance indicators, e.g., the number of defrost failures. A tailored simulator based on a mathematical model is used to perform the simulations in the different scenarios designed and to analyse the data obtained; Dymola and MATLAB/Simulink environments are exploited.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.