Background: Ex vivo fluorescence confocal microscopy (FCM) is an emerging technology that enables real-time, high-resolution digital imaging of freshly excised tissues without requiring standard histological preparation. This study aims to evaluate the diagnostic performance of FCM compared to conventional histology in a pediatric population with suspected oncological pathology. Materials and methods: A total of 18 tissue samples from pediatric patients with suspected oncological lesions were analyzed using FCM. The results were compared to the definitive diagnoses obtained via conventional histology, serving as the gold standard. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess the diagnostic accuracy. Cohen's kappa coefficient (K), 95% confidence interval (95%CI) and p-value were computed to evaluate the interobserver agreement and the concordance between FCM and histology. Results: FCM correctly identified 10 positive cases (true positives) and 7 negative cases (true negatives), with 1 false positive and no false negatives. Interobserver agreement was perfect, with a Cohen's kappa coefficient of 1.00 (95% CI: 0.81-1.00, p < 0.001). Sensitivity was 100% (95% CI: 72.2%-100%), specificity 87.5% (95% CI: 52.9%-97.8%), PPV 90.9% (95% CI: 62.3%-98.4%), and NPV 100% (95% CI: 64.6%-100%). The Cohen's kappa coefficient was 0.89, indicating excellent agreement between FCM and histology (95% CI: 0.67-1.10, p < 0.001). FCM provided rapid diagnostic results, significantly reducing turnaround time compared to conventional methods. Conclusions: FCM demonstrates exceptional diagnostic accuracy, with excellent sensitivity and specificity in evaluating pediatric specimens. Its ability to deliver reliable intraoperative results highlights its potential as a valuable adjunct to conventional histopathology in pediatric surgery. Larger studies are warranted to confirm these findings and establish its role in clinical practice.

Evaluating Ex Vivo Fluorescence Confocal Microscopy for Intraoperative Diagnosis in Pediatric Surgery: A Feasibility Study / Di Fabrizio, Donatella; Mastroberti, Francesca; Tavolario, Irene; Bindi, Edoardo; Ilari, Michele; Marinelli, Mario; Coccia, Paola; Filosa, Alessandra; Goteri, Gaia; Cobellis, Giovanni. - In: EUROPEAN JOURNAL OF PEDIATRIC SURGERY. - ISSN 0939-7248. - ELETTRONICO. - 36:1(2025), pp. 65-71. [10.1055/a-2676-2999]

Evaluating Ex Vivo Fluorescence Confocal Microscopy for Intraoperative Diagnosis in Pediatric Surgery: A Feasibility Study

Di Fabrizio, Donatella
;
Mastroberti, Francesca;Tavolario, Irene;Bindi, Edoardo;Marinelli, Mario;Coccia, Paola;Filosa, Alessandra;Goteri, Gaia;Cobellis, Giovanni
2025-01-01

Abstract

Background: Ex vivo fluorescence confocal microscopy (FCM) is an emerging technology that enables real-time, high-resolution digital imaging of freshly excised tissues without requiring standard histological preparation. This study aims to evaluate the diagnostic performance of FCM compared to conventional histology in a pediatric population with suspected oncological pathology. Materials and methods: A total of 18 tissue samples from pediatric patients with suspected oncological lesions were analyzed using FCM. The results were compared to the definitive diagnoses obtained via conventional histology, serving as the gold standard. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated to assess the diagnostic accuracy. Cohen's kappa coefficient (K), 95% confidence interval (95%CI) and p-value were computed to evaluate the interobserver agreement and the concordance between FCM and histology. Results: FCM correctly identified 10 positive cases (true positives) and 7 negative cases (true negatives), with 1 false positive and no false negatives. Interobserver agreement was perfect, with a Cohen's kappa coefficient of 1.00 (95% CI: 0.81-1.00, p < 0.001). Sensitivity was 100% (95% CI: 72.2%-100%), specificity 87.5% (95% CI: 52.9%-97.8%), PPV 90.9% (95% CI: 62.3%-98.4%), and NPV 100% (95% CI: 64.6%-100%). The Cohen's kappa coefficient was 0.89, indicating excellent agreement between FCM and histology (95% CI: 0.67-1.10, p < 0.001). FCM provided rapid diagnostic results, significantly reducing turnaround time compared to conventional methods. Conclusions: FCM demonstrates exceptional diagnostic accuracy, with excellent sensitivity and specificity in evaluating pediatric specimens. Its ability to deliver reliable intraoperative results highlights its potential as a valuable adjunct to conventional histopathology in pediatric surgery. Larger studies are warranted to confirm these findings and establish its role in clinical practice.
2025
children; conventional histology; ex vivo fluorescence confocal microscopy; pediatric; real-time
File in questo prodotto:
File Dimensione Formato  
Di Fabrizio_Evaluating-Ex-Vivo-Fluorescence-Confocal_2025.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 4.59 MB
Formato Adobe PDF
4.59 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/346452
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact