Background and objective In the literature, no studies correlate the effects of mandibular advancement devices (MADs) with different titration systems to periodontitis. Through a finite element analysis (FEA), this study investigates the effects generated on periodontal ligaments (PDLs) and teeth by four commercial MADs in periodontal health and with 15% bone resorption. Methods Four MADs (Somnodent Flex™, Somnodent Avant™, Orthoapnea™, and Herbst™) were digitalised starting from the impressions of a patient's dental arches. A force of 11.18 N, representing an advancement of 9.5 mm, was applied, and a FEA was subsequently performed. After measuring the stresses and displacements on the PDLs and teeth in healthy periodontal conditions, the vertical dimension of the alveolar bone was reduced by 15%, and measurements were repeated. Results In terms of PDL stress, Herbst™ is the device which guarantees a more uniform increment in case of the first stage of periodontitis (+7% for mandibular and maxillary PDLs compared to the healthy condition). For Somnodent™ devices, the PDLs stress increment is almost null for mandibular PDLs but much higher than Herbst™ for maxillary PDLs (+17% and +21% for Flex™ and Avant™). Orthoapnea™ determines a PDL stress augmentation between the other devices (+16% and +7%, respectively, for maxillary and mandibular PDLs). Concerning teeth movement, Herbst™ and Orthoapnea™ determine a lower and more uniform displacement than Somnodent devices. Conclusions The stress distribution and teeth displacement are strictly related to MAD geometry. Since its minor effects on teeth and PDLs, the Herbst™ could be more appropriate in patients with periodontitis.
Effects of Oral Appliances for Obstructive Sleep Apnoea in Reduced Periodontium: A Finite Element Analysis / Caragiuli, Manila; Candelari, Mara; Zalunardo, Francesca; Bruno, Giovanni; De Stefani, Alberto; Brunzini, Agnese; Mandolini, Marco. - In: INTERNATIONAL DENTAL JOURNAL. - ISSN 0020-6539. - (2024). [Epub ahead of print] [10.1016/j.identj.2024.05.002]
Effects of Oral Appliances for Obstructive Sleep Apnoea in Reduced Periodontium: A Finite Element Analysis
Caragiuli, Manila
Primo
Methodology
;Candelari, MaraFormal Analysis
;Brunzini, AgneseWriting – Original Draft Preparation
;Mandolini, MarcoUltimo
Writing – Original Draft Preparation
2024-01-01
Abstract
Background and objective In the literature, no studies correlate the effects of mandibular advancement devices (MADs) with different titration systems to periodontitis. Through a finite element analysis (FEA), this study investigates the effects generated on periodontal ligaments (PDLs) and teeth by four commercial MADs in periodontal health and with 15% bone resorption. Methods Four MADs (Somnodent Flex™, Somnodent Avant™, Orthoapnea™, and Herbst™) were digitalised starting from the impressions of a patient's dental arches. A force of 11.18 N, representing an advancement of 9.5 mm, was applied, and a FEA was subsequently performed. After measuring the stresses and displacements on the PDLs and teeth in healthy periodontal conditions, the vertical dimension of the alveolar bone was reduced by 15%, and measurements were repeated. Results In terms of PDL stress, Herbst™ is the device which guarantees a more uniform increment in case of the first stage of periodontitis (+7% for mandibular and maxillary PDLs compared to the healthy condition). For Somnodent™ devices, the PDLs stress increment is almost null for mandibular PDLs but much higher than Herbst™ for maxillary PDLs (+17% and +21% for Flex™ and Avant™). Orthoapnea™ determines a PDL stress augmentation between the other devices (+16% and +7%, respectively, for maxillary and mandibular PDLs). Concerning teeth movement, Herbst™ and Orthoapnea™ determine a lower and more uniform displacement than Somnodent devices. Conclusions The stress distribution and teeth displacement are strictly related to MAD geometry. Since its minor effects on teeth and PDLs, the Herbst™ could be more appropriate in patients with periodontitis.File | Dimensione | Formato | |
---|---|---|---|
Effects of Oral Appliances for Obstructive Sleep Apnoea.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso:
Creative commons
Dimensione
2.86 MB
Formato
Adobe PDF
|
2.86 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.