PurposeTo evaluate the clinical and radiographic outcomes of anterior cruciate (ACL) reconstruction at minimum 10-year follow-up.MethodsNinety-three patients who underwent primary unilateral ACL reconstruction with hamstring tendon autograft, transtibial technique and femoral cortico-cancellous screw suspension device (Athrax, Leader Medica s.r.l) between 2010 and 2012 were retrospectively reviewed. Mean follow-up was 136 months. Evaluation was performed using the International Knee Documentation Committee score (IKDC), Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm Knee Score and Tegner Activity Level Scale. Incidence of OA was determined by comparing standard anteroposterior and lateral weightbearing radiographs of the ACL-reconstructed and contralateral knee. Osteoarthritis severity was graded according to the Kellgren-Lawrence (KL) score.ResultsMedian Tegner activity level was 6 (5-7). Lysholm and IKDC scores were 100 (95-100) and 90 (86-95), respectively, KOOS was 98 (95-100). Of ACL-reconstructed knees, 41 (50%) had radiographic OA, of which 6 (7.3%) had severe OA (KL III). Of the contralateral healthy knees, 28 (34.1%) had radiographic evidence of OA. Of these 22 (26.8%) and 6 (7.3%) patients had, respectively, KL-I and KL-II. 11 patients (11.8%) underwent subsequent knee surgery: 5 (5.4%) revisions, 3 (3.2%) meniscal surgeries, 2 (2.2%) other surgeries, 1 (1.1%) contralateral ACL reconstruction.ConclusionsThe study demonstrates that ACL reconstruction with HT autograft and cortico-cancellous screw suspension device determines satisfying clinical results after 10 years of follow-up. From our cohort, a low rate of graft failure has been reported, even though almost 50% of patients present a knee OA greater or equal to grade II KL.
Ten-year outcomes of anterior cruciate ligament reconstruction with hamstring tendon autograft and femoral fixation with a cortico-cancellous screw suspension device / Senigagliesi, Elisa; Farinelli, Luca; Aquili, Alberto; Canè, Pier Paolo; Fravisini, Marco; Gigante, Antonio Pompilio. - In: EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY & TRAUMATOLOGY. - ISSN 1432-1068. - 34:2(2024), pp. 919-925. [10.1007/s00590-023-03740-6]
Ten-year outcomes of anterior cruciate ligament reconstruction with hamstring tendon autograft and femoral fixation with a cortico-cancellous screw suspension device
Senigagliesi, Elisa;Farinelli, Luca;Gigante, Antonio Pompilio
2024-01-01
Abstract
PurposeTo evaluate the clinical and radiographic outcomes of anterior cruciate (ACL) reconstruction at minimum 10-year follow-up.MethodsNinety-three patients who underwent primary unilateral ACL reconstruction with hamstring tendon autograft, transtibial technique and femoral cortico-cancellous screw suspension device (Athrax, Leader Medica s.r.l) between 2010 and 2012 were retrospectively reviewed. Mean follow-up was 136 months. Evaluation was performed using the International Knee Documentation Committee score (IKDC), Knee injury and Osteoarthritis Outcome Score (KOOS), Lysholm Knee Score and Tegner Activity Level Scale. Incidence of OA was determined by comparing standard anteroposterior and lateral weightbearing radiographs of the ACL-reconstructed and contralateral knee. Osteoarthritis severity was graded according to the Kellgren-Lawrence (KL) score.ResultsMedian Tegner activity level was 6 (5-7). Lysholm and IKDC scores were 100 (95-100) and 90 (86-95), respectively, KOOS was 98 (95-100). Of ACL-reconstructed knees, 41 (50%) had radiographic OA, of which 6 (7.3%) had severe OA (KL III). Of the contralateral healthy knees, 28 (34.1%) had radiographic evidence of OA. Of these 22 (26.8%) and 6 (7.3%) patients had, respectively, KL-I and KL-II. 11 patients (11.8%) underwent subsequent knee surgery: 5 (5.4%) revisions, 3 (3.2%) meniscal surgeries, 2 (2.2%) other surgeries, 1 (1.1%) contralateral ACL reconstruction.ConclusionsThe study demonstrates that ACL reconstruction with HT autograft and cortico-cancellous screw suspension device determines satisfying clinical results after 10 years of follow-up. From our cohort, a low rate of graft failure has been reported, even though almost 50% of patients present a knee OA greater or equal to grade II KL.File | Dimensione | Formato | |
---|---|---|---|
Senigagliesi_Ten-year-outcomes-anterior-cruciate_2024.pdf
accesso aperto
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso:
Creative commons
Dimensione
947.27 kB
Formato
Adobe PDF
|
947.27 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.