Moisture is one of the most important causes of deterioration of building materials, because water is involved in a lot of decay mechanisms. The problem results to be particularly relevant in the field of historic buildings, due to the fact that water presence could destroy great value elements and surfaces. To conserve this heritage is very important assess the features of water presence in masonry structures. Among the several non-destructive techniques that could be used on historic architectural heritage for moisture measurement, there is the microwave reflection method. In this paper are presented the first results of an in-situ campaign of moisture evaluation using microwave method on the church of S. Pietro in Valle (Fano, Marche Region, Italy), executed after a preliminary calibration of the test device. In this context results very important understand sources, penetration paths and spatial distribution of moisture to set up an effective conservation strategy of the monument

Microwave reflection method for moisture assessment for architectural heritage conservation: first results on the case study of church of S. Pietro in Valle (Fano, Italy) / Monni, Francesco; Gianangeli, Andrea; Quagliarini, Enrico; D’Orazio, Marco. - In: RESTAURO ARCHEOLOGICO. - ISSN 1724-9686. - 1(2023), pp. 558-565.

Microwave reflection method for moisture assessment for architectural heritage conservation: first results on the case study of church of S. Pietro in Valle (Fano, Italy)

Monni, Francesco
;
Gianangeli, Andrea;Quagliarini, Enrico;D’Orazio, Marco
2023-01-01

Abstract

Moisture is one of the most important causes of deterioration of building materials, because water is involved in a lot of decay mechanisms. The problem results to be particularly relevant in the field of historic buildings, due to the fact that water presence could destroy great value elements and surfaces. To conserve this heritage is very important assess the features of water presence in masonry structures. Among the several non-destructive techniques that could be used on historic architectural heritage for moisture measurement, there is the microwave reflection method. In this paper are presented the first results of an in-situ campaign of moisture evaluation using microwave method on the church of S. Pietro in Valle (Fano, Marche Region, Italy), executed after a preliminary calibration of the test device. In this context results very important understand sources, penetration paths and spatial distribution of moisture to set up an effective conservation strategy of the monument
2023
File in questo prodotto:
File Dimensione Formato  
Monni_et_al_RA_editorial_version_rid.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Creative commons
Dimensione 2.64 MB
Formato Adobe PDF
2.64 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/325591
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact