The present paper regards the proposal of an innovative low-cost ventilated load-bearing masonry using a new prefabricated dry-laid formwork wood-cement block with external interconnected holes forming a ventilated cavity. The aim of the work was to verify the performance of this solution by experimental and numerical comparison with other traditional and ventilated walls. To that end, an experimental campaign was carried out in summer on a simplified prototype involving the reproduction of the external ventilated cavity and the simultaneous measure of a ventilated cladding currently used. Numerical calculations on measure-calibrated models allowed to compare surface temperatures and heat fluxes for several ventilated and non-ventilated configurations. The results demonstrated that the proposed wall has a very high attenuation attitude on the crossing heat flows thus reducing summer gains. Moreover, the closing of the ventilation openings in winter and the use of the cavity as a still air gap also reduces the cold period dissipation. The costs are halved with respect to a traditional ventilated solution for the absence of the metal substructure.

Thermal performance of a new low-cost ventilated load bearing masonry with wood-cement blocks / Stazi, F.; Summa, S.; Roig, O.; Trozzi, G.; Di Perna, C.. - In: ENERGY AND BUILDINGS. - ISSN 0378-7788. - 297:(2023). [10.1016/j.enbuild.2023.113427]

Thermal performance of a new low-cost ventilated load bearing masonry with wood-cement blocks

Stazi, F.
;
Summa, S.;Trozzi, G.;Di Perna, C.
2023-01-01

Abstract

The present paper regards the proposal of an innovative low-cost ventilated load-bearing masonry using a new prefabricated dry-laid formwork wood-cement block with external interconnected holes forming a ventilated cavity. The aim of the work was to verify the performance of this solution by experimental and numerical comparison with other traditional and ventilated walls. To that end, an experimental campaign was carried out in summer on a simplified prototype involving the reproduction of the external ventilated cavity and the simultaneous measure of a ventilated cladding currently used. Numerical calculations on measure-calibrated models allowed to compare surface temperatures and heat fluxes for several ventilated and non-ventilated configurations. The results demonstrated that the proposed wall has a very high attenuation attitude on the crossing heat flows thus reducing summer gains. Moreover, the closing of the ventilation openings in winter and the use of the cavity as a still air gap also reduces the cold period dissipation. The costs are halved with respect to a traditional ventilated solution for the absence of the metal substructure.
2023
File in questo prodotto:
File Dimensione Formato  
paper.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 8.51 MB
Formato Adobe PDF
8.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Manuscript draft_low cost ventilated.pdf

embargo fino al 08/08/2025

Tipologia: Documento in post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza d'uso: Creative commons
Dimensione 6.98 MB
Formato Adobe PDF
6.98 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/321351
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact