BACKGROUND In patients with unexplained syncope and bifascicular block (BFB), syncope may be caused by intermittent atrioventricular (AV) block. When a correlation between syncope and bradyarrhythmia is not documented in these patients, 2 alternative management strategies can be adopted: (1) empiric pacemaker (PM) implantation or (2) long-term continuous electrocardio-graphic monitoring by implantable loop recorder (ILR).OBJECTIVE The purpose of this study was to compare the risk of syncope recurrence associated with empiric PM implantation or ILR monitoring.METHODS A prospective, multicenter, observational study enrolled consecutive patients with unexplained, recurrent, traumatic syncope and BFB who underwent ILR monitoring or empiric PM implantation. The risk and causes of syncope recurrence were assessed and compared between the 2 groups. Individual 1:1 propensity matching of baseline characteristics was performed.RESULTS A total of 309 consecutive patients (age 77.2 +/- 12.2 years; 60.8% male) were enrolled. Propensity matching yielded 89 matched pairs. After median follow-up of 33 months, empiric PM implantation was associated with a significantly lower risk of syncope recurrence than ILR monitoring (19.1 vs 46.1%; P <.001). A total of 35 patients (39.3%) who underwent ILR monitoring developed bradyarrhythmias (68.6% paroxysmal AV block) requiring PM implantation during follow-up. Excluding bradyarrhythmic syncope, the most frequent causes of syncope recurrence in both study groups were reflex syncope and orthostatic hypotension.CONCLUSION In patients with unexplained, recurrent, traumatic syncope and BFB, empiric PM implantation significantly reduced the risk of syncope recurrence in comparison with ILR monitoring. A high rate of patients who underwent ILR monitoring developed bradyarrhythmias requiring PM implantation.
Management of older patients with unexplained, recurrent, traumatic syncope and bifascicular block: Implantable loop recorder versus empiric pacemaker implantation-Results of a propensity-matched analysis / Palmisano, Pietro; Guerra, Federico; Aspromonte, Vittorio; Dell'Era, Gabriele; Pellegrino, Pier Luigi; Laffi, Mattia; Uran, Carlo; De Bonis, Silvana; Accogli, Michele; Dello Russo, Antonio; Patti, Giuseppe; Santoro, Francesco; Torriglia, Antonella; Nigro, Gerardo; Bisignani, Antonio; Coluccia, Giovanni; Stronati, Giulia; Russo, Vincenzo; Ammendola, Ernesto. - In: HEART RHYTHM. - ISSN 1547-5271. - 19:10(2022), pp. 1696-1703. [10.1016/j.hrthm.2022.05.023]
Management of older patients with unexplained, recurrent, traumatic syncope and bifascicular block: Implantable loop recorder versus empiric pacemaker implantation-Results of a propensity-matched analysis
Guerra, Federico;Dello Russo, Antonio;Santoro, Francesco;Stronati, Giulia;
2022-01-01
Abstract
BACKGROUND In patients with unexplained syncope and bifascicular block (BFB), syncope may be caused by intermittent atrioventricular (AV) block. When a correlation between syncope and bradyarrhythmia is not documented in these patients, 2 alternative management strategies can be adopted: (1) empiric pacemaker (PM) implantation or (2) long-term continuous electrocardio-graphic monitoring by implantable loop recorder (ILR).OBJECTIVE The purpose of this study was to compare the risk of syncope recurrence associated with empiric PM implantation or ILR monitoring.METHODS A prospective, multicenter, observational study enrolled consecutive patients with unexplained, recurrent, traumatic syncope and BFB who underwent ILR monitoring or empiric PM implantation. The risk and causes of syncope recurrence were assessed and compared between the 2 groups. Individual 1:1 propensity matching of baseline characteristics was performed.RESULTS A total of 309 consecutive patients (age 77.2 +/- 12.2 years; 60.8% male) were enrolled. Propensity matching yielded 89 matched pairs. After median follow-up of 33 months, empiric PM implantation was associated with a significantly lower risk of syncope recurrence than ILR monitoring (19.1 vs 46.1%; P <.001). A total of 35 patients (39.3%) who underwent ILR monitoring developed bradyarrhythmias (68.6% paroxysmal AV block) requiring PM implantation during follow-up. Excluding bradyarrhythmic syncope, the most frequent causes of syncope recurrence in both study groups were reflex syncope and orthostatic hypotension.CONCLUSION In patients with unexplained, recurrent, traumatic syncope and BFB, empiric PM implantation significantly reduced the risk of syncope recurrence in comparison with ILR monitoring. A high rate of patients who underwent ILR monitoring developed bradyarrhythmias requiring PM implantation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.