Aims: Patients with permanently increased risk of sudden cardiac death (SCD) can be protected by implantable cardioverter defibrillators (ICD). If an ICD must be removed due to infection, for example, immediate reimplantation might not be possible or indicated. The wearable cardioverter defibrillator (WCD) is an established, safe and effective solution to protect patients from SCD during this high-risk bridging period. Very few economic evaluations on WCD use are currently available. Methods: We conducted a systematic review to evaluate the available evidence of WCD in patients undergoing ICD explant/lead extraction. Additionally, a decision model was developed to compare use and costs of the WCD with standard therapy (in-hospital stay). For this purpose, a cost-minimization analysis was conducted, and complemented by a one-way sensitivity analysis. Results: In the base case scenario, the WCD was less expensive compared to standard therapy. The cost-minimization analysis showed a cost reduction of €1782 per patient using the WCD. If costs of standard care were changed, cost savings associated with the WCD varied from €3500 to €0, assuming costs for standard care of €6800 to €3600. Conclusion: After ICD explantation, patients can be safely and effectively protected from SCD after hospital discharge through WCD utilization. Furthermore, the use of a WCD for this patient group is cost saving when compared to standard therapy.

Cost-minimization analysis of a wearable cardioverter defibrillator in adult patients undergoing ICD explant procedures: Clinical and economic implications / Boriani, G.; Mantovani, L. G.; Cortesi, P. A.; De Ponti, R.; D'Onofrio, A.; Arena, G.; Curnis, A.; Forleo, G.; Guerra, F.; Porcu, M.; Sgarito, G.; Botto, G. L.. - In: CLINICAL CARDIOLOGY. - ISSN 0160-9289. - 44:11(2021), pp. 1497-1505. [10.1002/clc.23709]

Cost-minimization analysis of a wearable cardioverter defibrillator in adult patients undergoing ICD explant procedures: Clinical and economic implications

Guerra F.;
2021-01-01

Abstract

Aims: Patients with permanently increased risk of sudden cardiac death (SCD) can be protected by implantable cardioverter defibrillators (ICD). If an ICD must be removed due to infection, for example, immediate reimplantation might not be possible or indicated. The wearable cardioverter defibrillator (WCD) is an established, safe and effective solution to protect patients from SCD during this high-risk bridging period. Very few economic evaluations on WCD use are currently available. Methods: We conducted a systematic review to evaluate the available evidence of WCD in patients undergoing ICD explant/lead extraction. Additionally, a decision model was developed to compare use and costs of the WCD with standard therapy (in-hospital stay). For this purpose, a cost-minimization analysis was conducted, and complemented by a one-way sensitivity analysis. Results: In the base case scenario, the WCD was less expensive compared to standard therapy. The cost-minimization analysis showed a cost reduction of €1782 per patient using the WCD. If costs of standard care were changed, cost savings associated with the WCD varied from €3500 to €0, assuming costs for standard care of €6800 to €3600. Conclusion: After ICD explantation, patients can be safely and effectively protected from SCD after hospital discharge through WCD utilization. Furthermore, the use of a WCD for this patient group is cost saving when compared to standard therapy.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/313077
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 7
social impact