Objective: To measure the diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies among asymptomatic postmenopausal women, and to test the diagnostic accuracy and appropriateness of performed hysteroscopies.Study design: Prospective study of 268 asymptomatic postmenopausal women with endometrial thickness >= 4 mm referred to diagnostic hysteroscopy. The diagnostic accuracy of various endometrial thickness cut-off values was tested. Histological and hysteroscopic results were compared to measure the diagnostic accuracy of outpatient hysteroscopies.Results: No endometrial thickness cut-off values had optimal diagnostic accuracy [positive likelihood ratio (LR+) >10 and negative likelihood ratio (LR-) <0.1]. The best endometrial thickness cut-off value for the detection of all intra-uterine pathologies was >= 8 mm (LR+ 10.05 and LR- 0.22). An endometrial thickness cut-off value >= 10 mm did not miss any cases of endometrial cancer. The success rate of diagnostic hysteroscopy was 89%, but 97% of these revealed a benign intra-uterine pathology. The diagnostic accuracy of hysteroscopy was optimal for all intra-uterine pathologies, except endometrial hyperplasia (LR- 0.52).Conclusion: Using an endometrial thickness cut-off value >= 4 mm, only 3% of performed hysteroscopies were useful for the detection of pre-malignant or malignant lesions. Despite the finding that endometrial thickness did not show optimal diagnostic accuracy, using the best cut-off value (>= 8 mm) may be helpful to decrease the number of false-positive results. No cases of endometrial cancer were diagnosed in asymptomatic postmenopausal women with endometrial thickness <10 mm. (C) 2014 Elsevier Ireland Ltd. All rights reserved.

Diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies and appropriateness of performed hysteroscopies among asymptomatic postmenopausal women / Giannella, L; Mfuta, K; Setti, T; Boselli, F; Bergamini, E; Cerami, L B. - In: EUROPEAN JOURNAL OF OBSTETRICS, GYNECOLOGY, AND REPRODUCTIVE BIOLOGY. - ISSN 0301-2115. - 177:(2014), pp. 29-33. [10.1016/j.ejogrb.2014.03.025]

Diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies and appropriateness of performed hysteroscopies among asymptomatic postmenopausal women

Giannella, L
;
2014-01-01

Abstract

Objective: To measure the diagnostic accuracy of endometrial thickness for the detection of intra-uterine pathologies among asymptomatic postmenopausal women, and to test the diagnostic accuracy and appropriateness of performed hysteroscopies.Study design: Prospective study of 268 asymptomatic postmenopausal women with endometrial thickness >= 4 mm referred to diagnostic hysteroscopy. The diagnostic accuracy of various endometrial thickness cut-off values was tested. Histological and hysteroscopic results were compared to measure the diagnostic accuracy of outpatient hysteroscopies.Results: No endometrial thickness cut-off values had optimal diagnostic accuracy [positive likelihood ratio (LR+) >10 and negative likelihood ratio (LR-) <0.1]. The best endometrial thickness cut-off value for the detection of all intra-uterine pathologies was >= 8 mm (LR+ 10.05 and LR- 0.22). An endometrial thickness cut-off value >= 10 mm did not miss any cases of endometrial cancer. The success rate of diagnostic hysteroscopy was 89%, but 97% of these revealed a benign intra-uterine pathology. The diagnostic accuracy of hysteroscopy was optimal for all intra-uterine pathologies, except endometrial hyperplasia (LR- 0.52).Conclusion: Using an endometrial thickness cut-off value >= 4 mm, only 3% of performed hysteroscopies were useful for the detection of pre-malignant or malignant lesions. Despite the finding that endometrial thickness did not show optimal diagnostic accuracy, using the best cut-off value (>= 8 mm) may be helpful to decrease the number of false-positive results. No cases of endometrial cancer were diagnosed in asymptomatic postmenopausal women with endometrial thickness <10 mm. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/310118
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 10
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 37
social impact