In the present work, an improvement of protocol widely used for reporting the thermal behaviour of solar cookers is communicated to the scientific community. The linear regression used to represent the standardised cooking power is based on the well-known Hottel-Whillier-Bliss equation written in dimensionless format. The authors' new formulation procedure for estimating the standardised power includes a correction for the differ-ence between the load temperature and the ambient air temperature of the procedure of ASAE S580.1 Standard. It is derived from a simple theoretical deduction, similar to the ones usually applied to solar thermal flat col-lectors. The correction factor relates itself with the ratio between the measured solar irradiance and the solar irradiance chosen as a standard value. As one example, test results of a funnel cooker loaded with water are used to show the impact of the improvement of the procedure for reporting performance of a solar cooker. The procedure is valid only for solar cookers evidencing a clear linear performance curve.

Standardised power of solar cookers with a linear performance curve following the Hottel-Whillier-Bliss formulation / Ruivo, Cr; Coccia, G; Di Nicola, G; Carrillo-Andres, A; Apaolaza-Pagoaga, X. - In: RENEWABLE ENERGY. - ISSN 0960-1481. - 200:(2022), pp. 1202-1210. [10.1016/j.renene.2022.10.041]

Standardised power of solar cookers with a linear performance curve following the Hottel-Whillier-Bliss formulation

Coccia, G;Di Nicola, G;
2022-01-01

Abstract

In the present work, an improvement of protocol widely used for reporting the thermal behaviour of solar cookers is communicated to the scientific community. The linear regression used to represent the standardised cooking power is based on the well-known Hottel-Whillier-Bliss equation written in dimensionless format. The authors' new formulation procedure for estimating the standardised power includes a correction for the differ-ence between the load temperature and the ambient air temperature of the procedure of ASAE S580.1 Standard. It is derived from a simple theoretical deduction, similar to the ones usually applied to solar thermal flat col-lectors. The correction factor relates itself with the ratio between the measured solar irradiance and the solar irradiance chosen as a standard value. As one example, test results of a funnel cooker loaded with water are used to show the impact of the improvement of the procedure for reporting performance of a solar cooker. The procedure is valid only for solar cookers evidencing a clear linear performance curve.
2022
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/309808
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 6
social impact