The IEC 61000-4-21 and IEEE 299.1 documents report similar but not equal procedures to measure the shielding effectiveness (SE) of enclosures through the use of reverberation chambers. In this article, it is shown that these two measurement procedures can be merged in a single, enhanced, one. In particular, it is shown that the evaluation of the SE of enclosure in Annex H of IEC 61000-4-21, which exploits only mechanical stirring, can be improved by using the hybrid stirring, which includes also the frequency stirring, thus increasing the number of uncorrelated samples. On the other hand, it is shown that at low frequencies the evaluation of the SE of enclosures based on the definition in IEEE 299.1 can be improved through the use of the maximum values of measured powers rather than the average ones. The single, enhanced, proposed procedure provides more prudent SE values than the two standards at the low frequencies, especially for standard IEEE 299.1. The presented measurement approach is supported by results obtained in three different laboratories.

On the Shielding Effectiveness Calculation of Enclosures Through Measurements in Reverberation Chambers / Gifuni, A; Bastianelli, L; Gradoni, G; Moglie, F; Perna, S; Smartt, C; Primiani, Vm. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - STAMPA. - 63:5(2021), pp. 1395-1406. [10.1109/TEMC.2021.3057449]

On the Shielding Effectiveness Calculation of Enclosures Through Measurements in Reverberation Chambers

Bastianelli, L
Writing – Review & Editing
;
Gradoni, G
Writing – Review & Editing
;
Moglie, F
Writing – Review & Editing
;
Primiani, VM
Ultimo
Writing – Review & Editing
2021-01-01

Abstract

The IEC 61000-4-21 and IEEE 299.1 documents report similar but not equal procedures to measure the shielding effectiveness (SE) of enclosures through the use of reverberation chambers. In this article, it is shown that these two measurement procedures can be merged in a single, enhanced, one. In particular, it is shown that the evaluation of the SE of enclosure in Annex H of IEC 61000-4-21, which exploits only mechanical stirring, can be improved by using the hybrid stirring, which includes also the frequency stirring, thus increasing the number of uncorrelated samples. On the other hand, it is shown that at low frequencies the evaluation of the SE of enclosures based on the definition in IEEE 299.1 can be improved through the use of the maximum values of measured powers rather than the average ones. The single, enhanced, proposed procedure provides more prudent SE values than the two standards at the low frequencies, especially for standard IEEE 299.1. The presented measurement approach is supported by results obtained in three different laboratories.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/308592
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact