To analyze functional and anatomical response patterns to dexamethasone (DEX) implant in diabetic macular edema (DME), to describe proportion of responders and non-responders, and to propose a new DME grading system. Retrospective, multicenter, observational cohort study. Naïve and non-naïve DME patients were treated with DEX, with visual acuity (VA) ≥ 0.2 logMAR and central subfield thickness (CST) of ≥ 300 µm. Functional and anatomical responses were graded after 2 and 4 months, and categorized as early and stable improvement, early and progressive improvement, pendular response, delayed improvement, and persistent non-response. 417 eyes were included (175 treatment naïve eyes). Compared to non-naïve eyes, naïve eyes showed a very good functional response (VA gain ≥ 10 letters) more frequently after 2 and 4 months (56% and 57% [naïve] vs. 33% and 28% [non-naïve], p < 0.001). A VA gain < 5 letters (non-response) after 2 and 4 months was seen in 18% and 16% of naïve eyes, and in 49% and 53% of non-naïve eyes (p < 0.001). A lack of anatomical response was rare in both groups, but more frequently in non-naïve eyes (12% vs. 4%, p = 0.003). Functionally and anatomically, naïve eyes showed most frequently an early and stable improvement (functionally: 77/175 44%; anatomically: 123/175 eyes, 70%). Most non-naïve eyes experienced no significant improvement functionally (97/242 eyes, 40%), despite a mostly early and stable improvement anatomical response pattern (102/242 eyes, 42%). Functional but not anatomical response patterns were influenced by baseline VA. Naïve and non-naïve eyes show different functional and anatomical response patterns to DEX implant. Functional non-responders are rare in naïve eyes, whereas anatomical non-response is unusual in both groups.

GRAding of functional and anatomical response to DExamethasone implant in patients with Diabetic Macular Edema: GRADE-DME Study / Rodriguez-Valdes, P. J.; Rehak, M.; Zur, D.; Sala-Puigdollers, A.; Fraser-Bell, S.; Lupidi, M.; Chhablani, J.; Cebeci, Z.; Lains, I.; Chaikitmongkol, V.; Fung, A. T.; Okada, M.; Unterlauft, J. D.; Smadar, L.; Loewenstein, A.; Iglicki, M.; Busch, C.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 11:1(2021). [10.1038/s41598-020-79288-w]

GRAding of functional and anatomical response to DExamethasone implant in patients with Diabetic Macular Edema: GRADE-DME Study

Lupidi M.;
2021-01-01

Abstract

To analyze functional and anatomical response patterns to dexamethasone (DEX) implant in diabetic macular edema (DME), to describe proportion of responders and non-responders, and to propose a new DME grading system. Retrospective, multicenter, observational cohort study. Naïve and non-naïve DME patients were treated with DEX, with visual acuity (VA) ≥ 0.2 logMAR and central subfield thickness (CST) of ≥ 300 µm. Functional and anatomical responses were graded after 2 and 4 months, and categorized as early and stable improvement, early and progressive improvement, pendular response, delayed improvement, and persistent non-response. 417 eyes were included (175 treatment naïve eyes). Compared to non-naïve eyes, naïve eyes showed a very good functional response (VA gain ≥ 10 letters) more frequently after 2 and 4 months (56% and 57% [naïve] vs. 33% and 28% [non-naïve], p < 0.001). A VA gain < 5 letters (non-response) after 2 and 4 months was seen in 18% and 16% of naïve eyes, and in 49% and 53% of non-naïve eyes (p < 0.001). A lack of anatomical response was rare in both groups, but more frequently in non-naïve eyes (12% vs. 4%, p = 0.003). Functionally and anatomically, naïve eyes showed most frequently an early and stable improvement (functionally: 77/175 44%; anatomically: 123/175 eyes, 70%). Most non-naïve eyes experienced no significant improvement functionally (97/242 eyes, 40%), despite a mostly early and stable improvement anatomical response pattern (102/242 eyes, 42%). Functional but not anatomical response patterns were influenced by baseline VA. Naïve and non-naïve eyes show different functional and anatomical response patterns to DEX implant. Functional non-responders are rare in naïve eyes, whereas anatomical non-response is unusual in both groups.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/300735
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact