Background: Hypoglycin A has been recently identified has the causal agent of atypical myopathy (AM) in horses. Its identification and quantification in equine's biological fluids is thus a major concern to confirm maple poisoning and to provide insight into the poorly understood mechanism of hypoglycin A intoxication. Methods: Quantification of hypoglycin A has been achieved with the aTRAQ kit for amino acid analysis of physiological fluids (AB Sciex). Acquisition method on mass spectrometer has been updated to record the hypoglycin A specific MRM transition. Results: Outlined accuracy profiles demonstrated very reliable data. A good linearity was observed from 0.09 to 50. μmol/L and precision was very good with coefficient of variation below 8%. Fifty-five samples collected from 25 confirmed AM horses revealed significant hypoglycin A concentrations, while toxin was not found in serum of 8 control animals. Conclusions: The described aTRAQ variant method has been analytically and clinically validated. The reliability of our approach is thus demonstrated into the workup of atypical myopathy.

Quantification of hypoglycin A in serum using aTRAQ® assay / Boemer, F.; Deberg, M.; Schoos, R.; Baise, E.; Amory, H.; Gault, G.; Carlier, J.; Gaillard, Y.; Marcillaud-Pitel, C.; Votion, D.. - In: JOURNAL OF CHROMATOGRAPHY. B. - ISSN 1570-0232. - 997:(2015), pp. 75-80. [10.1016/j.jchromb.2015.06.004]

Quantification of hypoglycin A in serum using aTRAQ® assay

Carlier J.;
2015-01-01

Abstract

Background: Hypoglycin A has been recently identified has the causal agent of atypical myopathy (AM) in horses. Its identification and quantification in equine's biological fluids is thus a major concern to confirm maple poisoning and to provide insight into the poorly understood mechanism of hypoglycin A intoxication. Methods: Quantification of hypoglycin A has been achieved with the aTRAQ kit for amino acid analysis of physiological fluids (AB Sciex). Acquisition method on mass spectrometer has been updated to record the hypoglycin A specific MRM transition. Results: Outlined accuracy profiles demonstrated very reliable data. A good linearity was observed from 0.09 to 50. μmol/L and precision was very good with coefficient of variation below 8%. Fifty-five samples collected from 25 confirmed AM horses revealed significant hypoglycin A concentrations, while toxin was not found in serum of 8 control animals. Conclusions: The described aTRAQ variant method has been analytically and clinically validated. The reliability of our approach is thus demonstrated into the workup of atypical myopathy.
2015
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/300094
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 21
social impact