The triple point temperature of refrigerants is crucial because it serves as a reference for the lower limit of their use temperature in a refrigeration system. In this study, the triple point temperatures for recently proposed refrigerants with low global warming potential were experimentally determined. Ten hydro-fluoro-olefins, two hydro-chloro-fluoro-olefins, and trifluoroiodomethane were investigated. The triple point temperatures of the refrigerants were determined from the obtained cooling and heating curves. To improve measurement accuracy, measurements were conducted on samples obtained from different companies using two different measurement devices. The measured data were found to be in good agreement within the estimated measurement uncertainty.
Triple point measurements for new low- global-warming-potential refrigerants: Hydro-fluoro-olefins, hydro-chloro-fluoro-olefins, and trifluoroiodomethane / Tomassetti, S.; Nicola, G. D.; Kondou, C.. - In: INTERNATIONAL JOURNAL OF REFRIGERATION. - ISSN 0140-7007. - 133:(2022), pp. 172-180. [10.1016/j.ijrefrig.2021.10.008]
Triple point measurements for new low- global-warming-potential refrigerants: Hydro-fluoro-olefins, hydro-chloro-fluoro-olefins, and trifluoroiodomethane
Tomassetti S.;Nicola G. D.;
2022-01-01
Abstract
The triple point temperature of refrigerants is crucial because it serves as a reference for the lower limit of their use temperature in a refrigeration system. In this study, the triple point temperatures for recently proposed refrigerants with low global warming potential were experimentally determined. Ten hydro-fluoro-olefins, two hydro-chloro-fluoro-olefins, and trifluoroiodomethane were investigated. The triple point temperatures of the refrigerants were determined from the obtained cooling and heating curves. To improve measurement accuracy, measurements were conducted on samples obtained from different companies using two different measurement devices. The measured data were found to be in good agreement within the estimated measurement uncertainty.File | Dimensione | Formato | |
---|---|---|---|
1-s2.0-S0140700721004023-main.pdf
Solo gestori archivio
Tipologia:
Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso:
Tutti i diritti riservati
Dimensione
1.6 MB
Formato
Adobe PDF
|
1.6 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Tomassetti_Triple-point-measurements_2022_post-print.pdf
Open Access dal 22/10/2023
Tipologia:
Documento in post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza d'uso:
Creative commons
Dimensione
591.52 kB
Formato
Adobe PDF
|
591.52 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.