This paper discusses the electrical impedance behaviour, measured according to the Wenner’s method, of three different concrete mixes during accelerated degradation tests. Being a first attempt to move from laboratory to in-field applications targeted to long-term monitoring, the same electrode array configuration and set-up (AC current at 10 kHz) is used. Results show that electrical impedance decreases down to 24% in capillary water absorption tests, 77% and 86% in salt-spray chamber and wet/dry cycles with 3.5% NaCl solution, respectively. The two new low-clinker cements adopted seem to improve the measurement sensitivity towards contaminants ingress with respect to the commercial one (reference).

Performance of concretes manufactured with newly developed low-clinker cements exposed to water and chlorides: Characterization by means of electrical impedance measurements / Cosoli, G.; Mobili, A.; Giulietti, N.; Chiariotti, P.; Pandarese, G.; Tittarelli, F.; Bellezze, T.; Mikanovic, N.; Revel, G. M.. - In: CONSTRUCTION AND BUILDING MATERIALS. - ISSN 0950-0618. - STAMPA. - 271:121546(2021). [10.1016/j.conbuildmat.2020.121546]

Performance of concretes manufactured with newly developed low-clinker cements exposed to water and chlorides: Characterization by means of electrical impedance measurements

G. Cosoli;A. Mobili;G. Pandarese;F. Tittarelli;T. Bellezze;G. M. Revel
2021-01-01

Abstract

This paper discusses the electrical impedance behaviour, measured according to the Wenner’s method, of three different concrete mixes during accelerated degradation tests. Being a first attempt to move from laboratory to in-field applications targeted to long-term monitoring, the same electrode array configuration and set-up (AC current at 10 kHz) is used. Results show that electrical impedance decreases down to 24% in capillary water absorption tests, 77% and 86% in salt-spray chamber and wet/dry cycles with 3.5% NaCl solution, respectively. The two new low-clinker cements adopted seem to improve the measurement sensitivity towards contaminants ingress with respect to the commercial one (reference).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/295120
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 12