Background: Despite several clinical index tests that are currently applied for airway assessment, unpredicted difficult laryngoscopy may still represent a serious problem in anesthesia practice. The aim of this systematic review and meta-analysis was to evaluate whether preoperative airway ultrasound can predict difficult direct laryngoscopy in adult patients undergoing elective surgery under general anesthesia. Methods: We searched the Medline, Scopus, and Web of Science databases from their inception to December 2020. The population of interest included adults who required tracheal intubation for elective surgery under general anesthesia without clear anatomical abnormalities suggesting difficult laryngoscopy. A bivariate model has been used to assess the accuracy of each ultrasound index test to predict difficult direct laryngoscopy. Results: Fifteen studies have been considered for quantitative analysis of summary receiver operating characteristic (SROC). The sensitivity for distance from skin to epiglottis (DSE), distance from skin to hyoid bone (DSHB), and distance from skin to vocal cords (DSVC) was 0.82 (0.74-0.87), 0.71 (0.58-0.82), and 0.75 (0.62-0.84), respectively. The specificity for DSE, DSHB, and DSVC was 0.79 (0.70-0.87), 0.71 (0.57-0.82), and 0.72 (0.45-0.89), respectively. The area under the curve (AUC) for DSE, DSHB, DSVC, and ratio between the depth of the pre-epiglottic space and the distance from the epiglottis to the vocal cords (Pre-E/E-VC) was 0.87 (0.84-0.90), 0.77 (0.73-0.81), 0.78 (0.74-0.81), and 0.71 (0.67-0.75), respectively. Patients with difficult direct laryngoscopy have higher DSE, DSVC, and DSHB values than patients with easy laryngoscopy, with a mean difference of 0.38 cm (95% confidence interval [CI], 0.17-0.58 cm; P = .0004), 0.18 cm (95% CI, 0.01-0.35 cm; P = .04), and 0.23 cm (95% CI, 0.08-0.39 cm; P = .004), respectively. Conclusions: Our study demonstrates that airway ultrasound index tests are significantly different between patients with easy versus difficult direct laryngoscopy, and the DSE is the most studied index test in literature to predict difficult direct laryngoscopy. However, it is not currently possible to reach a definitive conclusion. Further studies are needed with better standardization of ultrasound assessment to limit all possible sources of heterogeneity.

Airway Ultrasound as Predictor of Difficult Direct Laryngoscopy: A Systematic Review and Meta-analysis / Carsetti, Andrea; Sorbello, Massimiliano; Adrario, Erica; Donati, Abele; Falcetta, Stefano. - In: ANESTHESIA AND ANALGESIA. - ISSN 0003-2999. - STAMPA. - 134:4(2022), pp. 740-750. [10.1213/ANE.0000000000005839]

Airway Ultrasound as Predictor of Difficult Direct Laryngoscopy: A Systematic Review and Meta-analysis

Carsetti, Andrea
Primo
;
Adrario, Erica;Donati, Abele;
2022-01-01

Abstract

Background: Despite several clinical index tests that are currently applied for airway assessment, unpredicted difficult laryngoscopy may still represent a serious problem in anesthesia practice. The aim of this systematic review and meta-analysis was to evaluate whether preoperative airway ultrasound can predict difficult direct laryngoscopy in adult patients undergoing elective surgery under general anesthesia. Methods: We searched the Medline, Scopus, and Web of Science databases from their inception to December 2020. The population of interest included adults who required tracheal intubation for elective surgery under general anesthesia without clear anatomical abnormalities suggesting difficult laryngoscopy. A bivariate model has been used to assess the accuracy of each ultrasound index test to predict difficult direct laryngoscopy. Results: Fifteen studies have been considered for quantitative analysis of summary receiver operating characteristic (SROC). The sensitivity for distance from skin to epiglottis (DSE), distance from skin to hyoid bone (DSHB), and distance from skin to vocal cords (DSVC) was 0.82 (0.74-0.87), 0.71 (0.58-0.82), and 0.75 (0.62-0.84), respectively. The specificity for DSE, DSHB, and DSVC was 0.79 (0.70-0.87), 0.71 (0.57-0.82), and 0.72 (0.45-0.89), respectively. The area under the curve (AUC) for DSE, DSHB, DSVC, and ratio between the depth of the pre-epiglottic space and the distance from the epiglottis to the vocal cords (Pre-E/E-VC) was 0.87 (0.84-0.90), 0.77 (0.73-0.81), 0.78 (0.74-0.81), and 0.71 (0.67-0.75), respectively. Patients with difficult direct laryngoscopy have higher DSE, DSVC, and DSHB values than patients with easy laryngoscopy, with a mean difference of 0.38 cm (95% confidence interval [CI], 0.17-0.58 cm; P = .0004), 0.18 cm (95% CI, 0.01-0.35 cm; P = .04), and 0.23 cm (95% CI, 0.08-0.39 cm; P = .004), respectively. Conclusions: Our study demonstrates that airway ultrasound index tests are significantly different between patients with easy versus difficult direct laryngoscopy, and the DSE is the most studied index test in literature to predict difficult direct laryngoscopy. However, it is not currently possible to reach a definitive conclusion. Further studies are needed with better standardization of ultrasound assessment to limit all possible sources of heterogeneity.
2022
File in questo prodotto:
File Dimensione Formato  
airway_ultrasound_as_predictor_of_difficult_direct.15.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Creative commons
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/293982
Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 52
social impact