Energy efficiency interventions in Water Supply Systems (WSSs) need a precise evaluation of the available water flow rates for energy recovery interventions; however, flow meters are generally too costly for being installed in all the gravity adduction pipelines of a WSS. This paper presents a methodology for predicting flow rates in gravity adduction pipelines based on the electricity bill consumption. In this study, the predicted average flow rate is 0.0300 m3∗s−1, being 1.64% lower than the real one. A Pelton turbine has been chosen as energy recovery unit for supplying electricity to a pumping station of a preloading tank where the water is treated to make it drinkable. An energy saving of 475.26 (MW∗h)∗year−1 is achieved, which can be also expressed as 88.87 saved Tonnes of Oil Equivalent (TOE) and 204.36 ktCO2 not released into the atmosphere. The gross economic saving due to the installation of the Pelton turbine is equal to 94.29 k€∗year−1 and it can be further increased up to 116.51 k€∗year−1 if the energy efficiency certificates issued by the Italian Authorities are considered. The Payback Period (PBP) of the intervention corresponds to 3 years, and a Net Present Value (NPV) after twenty years is approximately 1.4 M€.

A methodology to estimate average flow rates in Water Supply Systems (WSSs) for energy recovery purposes through hydropower solutions / Rossi, Mosè; Spedaletti, Samuele; Lorenzetti, Matteo; Salvi, Danilo; Renzi, Massimiliano; Comodi, Gabriele; Caresana, Flavio; Pelagalli, Leonardo. - In: RENEWABLE ENERGY. - ISSN 0960-1481. - 180:(2021), pp. 1101-1113. [10.1016/j.renene.2021.09.005]

A methodology to estimate average flow rates in Water Supply Systems (WSSs) for energy recovery purposes through hydropower solutions

Rossi, Mosè;Spedaletti, Samuele;Comodi, Gabriele
;
Caresana, Flavio;Pelagalli, Leonardo
2021-01-01

Abstract

Energy efficiency interventions in Water Supply Systems (WSSs) need a precise evaluation of the available water flow rates for energy recovery interventions; however, flow meters are generally too costly for being installed in all the gravity adduction pipelines of a WSS. This paper presents a methodology for predicting flow rates in gravity adduction pipelines based on the electricity bill consumption. In this study, the predicted average flow rate is 0.0300 m3∗s−1, being 1.64% lower than the real one. A Pelton turbine has been chosen as energy recovery unit for supplying electricity to a pumping station of a preloading tank where the water is treated to make it drinkable. An energy saving of 475.26 (MW∗h)∗year−1 is achieved, which can be also expressed as 88.87 saved Tonnes of Oil Equivalent (TOE) and 204.36 ktCO2 not released into the atmosphere. The gross economic saving due to the installation of the Pelton turbine is equal to 94.29 k€∗year−1 and it can be further increased up to 116.51 k€∗year−1 if the energy efficiency certificates issued by the Italian Authorities are considered. The Payback Period (PBP) of the intervention corresponds to 3 years, and a Net Present Value (NPV) after twenty years is approximately 1.4 M€.
2021
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0960148121013033-main.pdf

Solo gestori archivio

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza d'uso: Tutti i diritti riservati
Dimensione 1.84 MB
Formato Adobe PDF
1.84 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
1-s2.0-S0960148121013033_post-print.pdf

Open Access dal 12/09/2023

Tipologia: Documento in post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza d'uso: Creative commons
Dimensione 2.04 MB
Formato Adobe PDF
2.04 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/291992
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact