In this paper, the microstructure, defects, hardness, and tensile strength of the 17-4PH specimens manufactured additively using the selective laser melting (SLM) technique were studied. The analyzed parts (10 mm size cubic specimens and tensile specimens) were manufactured with different defocus parameter values (-1, 0, +1 mm) in order to evaluate this effect with a low power laser (38 W). The study was carried out on three different sections of each cubic specimen, one perpendicular to the laser beam or SLM manufacturing direction (transversal section), and another two parallel to the laser beam direction (longitudinal sections). The specimens microstructures were analyzed with an X-ray diffraction technique, as well as optical, scanning electron, and transmission electron microscopes. Image J software was used to characterize the defects and phase ratio. In addition, hardness and tensile tests were performed according to the corresponding standards. The results show that the amount of austenitic phase and the average grain size varied with defocusing. The percentage of defective area was less than 0.25%. The analyzed defocus distance did not affect the number and average size of the defects. Adjusting the defocusing SLM parameter is important for manufacturing parts with good mechanical properties.

Laser Defocusing Effect on the Microstructure and Defects of 17-4PH Parts Additively Manufactured by SLM at a Low Energy Input / Leo, P.; Cabibbo, M.; Prete, A. D.; Giganto, S.; Martínez-Pellitero, S.; Barreiro., J.. - In: METALS. - ISSN 2075-4701. - ELETTRONICO. - 11:4(2021), p. 588. [10.3390/met11040588]

Laser Defocusing Effect on the Microstructure and Defects of 17-4PH Parts Additively Manufactured by SLM at a Low Energy Input

M. Cabibbo
Investigation
;
2021-01-01

Abstract

In this paper, the microstructure, defects, hardness, and tensile strength of the 17-4PH specimens manufactured additively using the selective laser melting (SLM) technique were studied. The analyzed parts (10 mm size cubic specimens and tensile specimens) were manufactured with different defocus parameter values (-1, 0, +1 mm) in order to evaluate this effect with a low power laser (38 W). The study was carried out on three different sections of each cubic specimen, one perpendicular to the laser beam or SLM manufacturing direction (transversal section), and another two parallel to the laser beam direction (longitudinal sections). The specimens microstructures were analyzed with an X-ray diffraction technique, as well as optical, scanning electron, and transmission electron microscopes. Image J software was used to characterize the defects and phase ratio. In addition, hardness and tensile tests were performed according to the corresponding standards. The results show that the amount of austenitic phase and the average grain size varied with defocusing. The percentage of defective area was less than 0.25%. The analyzed defocus distance did not affect the number and average size of the defects. Adjusting the defocusing SLM parameter is important for manufacturing parts with good mechanical properties.
2021
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/291513
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 14
social impact