The efficacy of an air‐cleaning device equipped with a high efficiency particulate air (HEPA) filter (without further avoidance measures) was studied in patients allergic to house dust mite. The effects of the air‐cleaner on indoor Dermatophagoides sp. levels, symptom score and bronchial hyperresponsiveness in nine mite‐allergic patients were assessed using a cross‐over controlled study. No significant effect was demonstrated on indoor Dermatophagoides sp. levels when comparing the period of air‐cleaner activity (2 months) with the control period (2 months). The Dermatophagoides sp. levels in the houses studied were lower than the risk level for asthmatic attacks, making it difficult to assess any effect on asthma; however, neither bronchial hyperresponsiveness nor rhinitis symptom score were changed by air‐cleaner activity. During the trial period, however the mean level of Dermatophagoides sp. allergen in the houses changed spontaneously from 4.4 Hg/g (mean level in the first 2 trial months) to 1. 75 μg/g of dust (second 2 months) (P < 0.05). Owing to this change, the mean rhinitis symptom score also decreased (P < 0.05), even if no significant correlation was demonstrated (r = 0.4 P= 0.089). HEPA filter air‐cleaners appear insufficient as substitutes for standard avoidance measures in mite allergic patients. Copyright © 1991, Wiley Blackwell. All rights reserved

Efficacy of an air‐cleaning device equipped with a high efficiency particulate air filter in house dust mite respiratory allergy / Antonicelli, L.; Bilo, M. B.; Pucci, S.; Schou, C.; Bonifazi, F.. - In: ALLERGY. - ISSN 0105-4538. - 46:8(1991), pp. 594-600. [10.1111/j.1398-9995.1991.tb00629.x]

Efficacy of an air‐cleaning device equipped with a high efficiency particulate air filter in house dust mite respiratory allergy

Bilo M. B.
Writing – Original Draft Preparation
;
1991-01-01

Abstract

The efficacy of an air‐cleaning device equipped with a high efficiency particulate air (HEPA) filter (without further avoidance measures) was studied in patients allergic to house dust mite. The effects of the air‐cleaner on indoor Dermatophagoides sp. levels, symptom score and bronchial hyperresponsiveness in nine mite‐allergic patients were assessed using a cross‐over controlled study. No significant effect was demonstrated on indoor Dermatophagoides sp. levels when comparing the period of air‐cleaner activity (2 months) with the control period (2 months). The Dermatophagoides sp. levels in the houses studied were lower than the risk level for asthmatic attacks, making it difficult to assess any effect on asthma; however, neither bronchial hyperresponsiveness nor rhinitis symptom score were changed by air‐cleaner activity. During the trial period, however the mean level of Dermatophagoides sp. allergen in the houses changed spontaneously from 4.4 Hg/g (mean level in the first 2 trial months) to 1. 75 μg/g of dust (second 2 months) (P < 0.05). Owing to this change, the mean rhinitis symptom score also decreased (P < 0.05), even if no significant correlation was demonstrated (r = 0.4 P= 0.089). HEPA filter air‐cleaners appear insufficient as substitutes for standard avoidance measures in mite allergic patients. Copyright © 1991, Wiley Blackwell. All rights reserved
1991
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/282954
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 13
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 54
social impact