Key Clinical Message Transvenous extraction of Riata lead could be a challenging procedure due to insulation failure and conductor cables' externalization through the eroded outer insulation. In this case, a complete lead extraction was achieved through a combined LASER and femoral approach because of the massive conductors' externalization.
Combined LASER and femoral approach to remove a previous failure of Riata lead extraction
Dello Russo, Antonio;Casella, Michela;
2017-01-01
Abstract
Key Clinical Message Transvenous extraction of Riata lead could be a challenging procedure due to insulation failure and conductor cables' externalization through the eroded outer insulation. In this case, a complete lead extraction was achieved through a combined LASER and femoral approach because of the massive conductors' externalization.File in questo prodotto: