Purpose: In the present study, we aimed to test the value of CAAP-AF score for prediction of atrial fibrillation (AF) recurrence at follow-up in a group of our patients treated by balloon cryoablation. Methods: A total of 283 symptomatic drug-refractory AF patients [261 (92%) with paroxysmal AF] who underwent pulmonary vein isolation (PVI) with second-generation cryoballoon between April 2012 and October 2016 were included. The CAAP-AF score was calculated for every patient. Results: A total of 283 patients [68 female (20%), mean age 59.8 ± 11.4 years] were included in the present analysis. Eighty-nine patients (31%) had hypertension and 13 (4%) had coronary artery disease. The mean left atrial diameter and left ventricular ejection fraction were 40.6 ± 7.0 mm and 60.0 ± 9.1%, respectively. The mean CHA2DS2-VASc score was 1.2 ± 1.1, and mean number of prior failed antiarrhythmic drugs was 1.4 ± 0.8. At 18 ± 6 months follow-up, 25 patients (8.87%) developed AF recurrence. The recurrence rate was as follows: 3.17% (score 0–3), 8.47% (score 4), 16.28% (score 5), 6.67% (score 6), 23.08% (score 7), and 36.36% (score ≥8). The recurrence rate was 4.86% at a score <5 and 16.49% at a value ≥5; a score cutoff ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%. Conclusions: The present analysis suggests the usefulness of CAAP-AF scoring system, with its simple and easily obtained six clinical variables, to predict AF recurrence after PVI by means of second-generation cryoballoon. A score value ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%.

Predictors of arrhythmia recurrence after balloon cryoablation of atrial fibrillation: the value of CAAP-AF risk scoring system / Sanhoury, M.; Moltrasio, M.; Tundo, F.; Riva, S.; Dello Russo, A.; Casella, M.; Tondo, C.; Fassini, G.. - In: JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY. - ISSN 1383-875X. - 49:2(2017), pp. 129-135. [10.1007/s10840-017-0248-4]

Predictors of arrhythmia recurrence after balloon cryoablation of atrial fibrillation: the value of CAAP-AF risk scoring system

Dello Russo A.;Casella M.;
2017-01-01

Abstract

Purpose: In the present study, we aimed to test the value of CAAP-AF score for prediction of atrial fibrillation (AF) recurrence at follow-up in a group of our patients treated by balloon cryoablation. Methods: A total of 283 symptomatic drug-refractory AF patients [261 (92%) with paroxysmal AF] who underwent pulmonary vein isolation (PVI) with second-generation cryoballoon between April 2012 and October 2016 were included. The CAAP-AF score was calculated for every patient. Results: A total of 283 patients [68 female (20%), mean age 59.8 ± 11.4 years] were included in the present analysis. Eighty-nine patients (31%) had hypertension and 13 (4%) had coronary artery disease. The mean left atrial diameter and left ventricular ejection fraction were 40.6 ± 7.0 mm and 60.0 ± 9.1%, respectively. The mean CHA2DS2-VASc score was 1.2 ± 1.1, and mean number of prior failed antiarrhythmic drugs was 1.4 ± 0.8. At 18 ± 6 months follow-up, 25 patients (8.87%) developed AF recurrence. The recurrence rate was as follows: 3.17% (score 0–3), 8.47% (score 4), 16.28% (score 5), 6.67% (score 6), 23.08% (score 7), and 36.36% (score ≥8). The recurrence rate was 4.86% at a score <5 and 16.49% at a value ≥5; a score cutoff ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%. Conclusions: The present analysis suggests the usefulness of CAAP-AF scoring system, with its simple and easily obtained six clinical variables, to predict AF recurrence after PVI by means of second-generation cryoballoon. A score value ≥5 predicted AF recurrence with a sensitivity 64% and specificity 68%.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/275717
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 14
social impact