Background: Atrial fibrillation (AF) is associated with increased morbidity and mortality in patients suffering from heart failure (HF). Patients in New York Heart Association HF classes III or IV, with systolic dysfunction and a wide QRS, are candidates for cardiac resynchronization therapy (CRT), and might benefit from atrial overdrive pacing (AOP). Methods: The Management of Atrial fibrillation Suppression in AF-HF COmorbidity Therapy (MASCOT) trial enrolled 409 CRT device recipients (79% men), who were randomly assigned to AOP ON (n = 197), versus AOP OFF (n = 197) and followed up for 1 year. Their mean age was 68 ± 10 years, left ventricular ejection fraction 25 ± 6%, QRS duration 163 ± 29 milliseconds. New York Heart Association class III was present in 86% of patients and 19% had a history of paroxysmal AF. The primary study end point was incidence of permanent AF at 1 year. Results: Atrial overdrive pacing increased the percentage of atrial pacing from 30% to 80% (P < .0001), was well tolerated, and did not interfere with (a) delivery of CRT (95% mean ventricular pacing in both groups), (b) response to CRT (70% responders in the control vs 67% in the treatment group), or (c) cardiac function (left ventricular ejection fraction increased from 24.5% ± 6.2% to 32.7% ± 10.9% in the control and from 25.8% ± 6.8% to 33.1% ± 12.6% in the treatment group). The incidence of permanent AF was 3.3% in both groups. By logistic regression analysis, a history of AF (P < .001) and absence of antiarrhythmic drugs (P = .002) were associated with permanent AF. Conclusions: In this first trial of a specific AF prevention algorithm in CRT recipients, AOP was safe and did not worsen HF. The prevention algorithm did not lower the 1-year incidence of AF. © 2008 Mosby, Inc. All rights reserved.

Atrial fibrillation in recipients of cardiac resynchronization therapy device: 1-year results of the randomized MASCOT trial / Padeletti, L.; Muto, C.; Maounis, T.; Schuchert, A.; Bongiorni, M. -G.; Frank, R.; Vesterlund, T.; Brachmann, J.; Vicentini, A.; Jauvert, G.; Tadeo, G.; Gras, D.; Lisi, F.; Dello Russo, A.; Rey, J. -L.; Boulogne, E.; Ricciardi, G.. - In: AMERICAN HEART JOURNAL. - ISSN 0002-8703. - 156:3(2008), pp. 520-526. [10.1016/j.ahj.2008.04.013]

Atrial fibrillation in recipients of cardiac resynchronization therapy device: 1-year results of the randomized MASCOT trial

Dello Russo A.;
2008-01-01

Abstract

Background: Atrial fibrillation (AF) is associated with increased morbidity and mortality in patients suffering from heart failure (HF). Patients in New York Heart Association HF classes III or IV, with systolic dysfunction and a wide QRS, are candidates for cardiac resynchronization therapy (CRT), and might benefit from atrial overdrive pacing (AOP). Methods: The Management of Atrial fibrillation Suppression in AF-HF COmorbidity Therapy (MASCOT) trial enrolled 409 CRT device recipients (79% men), who were randomly assigned to AOP ON (n = 197), versus AOP OFF (n = 197) and followed up for 1 year. Their mean age was 68 ± 10 years, left ventricular ejection fraction 25 ± 6%, QRS duration 163 ± 29 milliseconds. New York Heart Association class III was present in 86% of patients and 19% had a history of paroxysmal AF. The primary study end point was incidence of permanent AF at 1 year. Results: Atrial overdrive pacing increased the percentage of atrial pacing from 30% to 80% (P < .0001), was well tolerated, and did not interfere with (a) delivery of CRT (95% mean ventricular pacing in both groups), (b) response to CRT (70% responders in the control vs 67% in the treatment group), or (c) cardiac function (left ventricular ejection fraction increased from 24.5% ± 6.2% to 32.7% ± 10.9% in the control and from 25.8% ± 6.8% to 33.1% ± 12.6% in the treatment group). The incidence of permanent AF was 3.3% in both groups. By logistic regression analysis, a history of AF (P < .001) and absence of antiarrhythmic drugs (P = .002) were associated with permanent AF. Conclusions: In this first trial of a specific AF prevention algorithm in CRT recipients, AOP was safe and did not worsen HF. The prevention algorithm did not lower the 1-year incidence of AF. © 2008 Mosby, Inc. All rights reserved.
2008
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/275032
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 15
social impact