Background: The visually guided laser ablation (VGLA) catheter is a compliant, variable-diameter balloon that delivers laser energy around the pulmonary vein (PV) ostium under real-time endoscopic visualization. While acute PV isolation has been shown to be feasible, limited data exist regarding the durability of isolation. Objective: We sought to determine the durability of PV isolation following ablation using the balloon-based VGLA catheter. Methods: The VGLA catheter was evaluated in patients with paroxysmal atrial fibrillation (3 sites, 10 operators). Following transseptal puncture, the VGLA catheter was advanced through a 12-F deflectable sheath and inflated at the target PV ostium. Under endoscopic guidance, the 30° aiming arc was maneuvered around the PV and laser energy was delivered to ablate tissue in a contiguous/overlapping manner. At ∼3 months, all patients returned for a PV remapping procedure. Results: In 56 patients, 202 of 206 PVs (98%) were acutely isolated. At 105 ± 44 (mean ± SD) days, 52 patients returned for PV remapping at which time 162 of 189 PVs (86%) remained isolated and 32 of 52 patients (62%) had all PVs still isolated. On comparing the operators performing <10 vs <10 procedures, the durable PV isolation rate and the percentage of patients with all PVs isolated were found to be 73% vs 89% (P =.011) and 57% vs 66% (P =.746), respectively. After 2 procedures and 12.0 ± 1.9 months of follow-up, the drug-free rate of freedom from atrial fibrillation was 71.2%. Conclusions: In this multicenter, multioperator experience, VGLA resulted in a very high rate of durable PV isolation with a clinical efficacy similar to that of radiofrequency ablation. © 2012 Heart Rhythm Society. All rights reserved.

The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies / 69., Bartoletti S; Pelargonio, G; Dello Russo, A; Casella, M; Tondo, C. - In: HEART RHYTHM. - ISSN 1547-5271. - 9:6(2012), pp. 919-925. [10.1016/j.hrthm.2012.01.019]

The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies

Dello Russo A;Casella M;
2012-01-01

Abstract

Background: The visually guided laser ablation (VGLA) catheter is a compliant, variable-diameter balloon that delivers laser energy around the pulmonary vein (PV) ostium under real-time endoscopic visualization. While acute PV isolation has been shown to be feasible, limited data exist regarding the durability of isolation. Objective: We sought to determine the durability of PV isolation following ablation using the balloon-based VGLA catheter. Methods: The VGLA catheter was evaluated in patients with paroxysmal atrial fibrillation (3 sites, 10 operators). Following transseptal puncture, the VGLA catheter was advanced through a 12-F deflectable sheath and inflated at the target PV ostium. Under endoscopic guidance, the 30° aiming arc was maneuvered around the PV and laser energy was delivered to ablate tissue in a contiguous/overlapping manner. At ∼3 months, all patients returned for a PV remapping procedure. Results: In 56 patients, 202 of 206 PVs (98%) were acutely isolated. At 105 ± 44 (mean ± SD) days, 52 patients returned for PV remapping at which time 162 of 189 PVs (86%) remained isolated and 32 of 52 patients (62%) had all PVs still isolated. On comparing the operators performing <10 vs <10 procedures, the durable PV isolation rate and the percentage of patients with all PVs isolated were found to be 73% vs 89% (P =.011) and 57% vs 66% (P =.746), respectively. After 2 procedures and 12.0 ± 1.9 months of follow-up, the drug-free rate of freedom from atrial fibrillation was 71.2%. Conclusions: In this multicenter, multioperator experience, VGLA resulted in a very high rate of durable PV isolation with a clinical efficacy similar to that of radiofrequency ablation. © 2012 Heart Rhythm Society. All rights reserved.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/274934
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 24
  • Scopus 129
  • ???jsp.display-item.citation.isi??? 125
social impact