The investigation of the thermal properties of an array of microbolometers has been carried out by mean of two independent numerical analysis, respectively the Direct-Simulation Monte Carlo (DSMC) and the classic diffusive approach of the Fourier’s equation. In particular, the thermal dissipation of a hot membrane placed in a low-pressure cavity has been studied for different values of the temperature of the hot body and for different values of the pressure of the environment. The results for the heat flux derived from the two approaches have then been compared and discussed
Advanced numerical investigation of the heat flux in an array of microbolometers / Stocchi, M.; Mencarelli, D.; Pierantoni, L.; Goritz, A.; Kaynak, C. B.; Wietstruck, M.; Kaynak, M.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - ELETTRONICO. - 9:1(2019), pp. 11078-11086. [10.1038/s41598-019-47472-2]
Advanced numerical investigation of the heat flux in an array of microbolometers
Stocchi M.;Mencarelli D.;Pierantoni L.
;
2019-01-01
Abstract
The investigation of the thermal properties of an array of microbolometers has been carried out by mean of two independent numerical analysis, respectively the Direct-Simulation Monte Carlo (DSMC) and the classic diffusive approach of the Fourier’s equation. In particular, the thermal dissipation of a hot membrane placed in a low-pressure cavity has been studied for different values of the temperature of the hot body and for different values of the pressure of the environment. The results for the heat flux derived from the two approaches have then been compared and discussedI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.