Aim: The aim of this study was to perform a cross-reactivity investigation of six benzofurans with immunoassays (IAs) screening tests for amphetamines and ecstasy in urine samples. Methods: The following benzofuranes were investigated: 5-(2-Methylaminopropyl)Benzofuran (5-MAPB), 5-(2-methylaminopropyl)-2,3-dihydrobenzofuran (5-MAPDB), 5-(2-Aminopropyl)-Benzofuran (5-APB), 5-(2-Aminopropyl)-2,3-dihydrobenzofuran (5-APDB), 5-(2-Ethylaminopropyl)Benzofuran (5-EAPB) and 5-(2-Aminoethyl)-2,3-dihydrobenzofuran (5-AEDB). The study was performed with urine-free spiked samples and authentic urine samples using eight different IAs for amphetamines and ecstasy. Results: All evaluated benzofurans showed cross-reactivity in some of the IAs tested, except for 5-AEDB. Urine samples of an intoxication case involving 5-MAPB, 5-APB and 5-EAPB were also positives in the IAs tested. Conclusion: There is an important variability in the cross-reactivity of the IAs for amphetamine and ecstasy caused by benzofurans depending on the immunoassay employed and the tested compounds. © 2017 Future Science Ltd.
Cross-reactivity of selected benzofurans with commercial amphetamine and ecstasy immunoassays in urine / Gomila, I.; Moranta, C.; Quesada, L.; Pastor, Y.; Dastis, M.; Torrents, A.; Elorza, M. Á.; Busardò, F. P.; Barceló, B.. - In: BIOANALYSIS. - ISSN 1757-6180. - 9:22(2017), pp. 1771-1785. [10.4155/bio-2017-0191]
Cross-reactivity of selected benzofurans with commercial amphetamine and ecstasy immunoassays in urine
Busardò, F. P.;
2017-01-01
Abstract
Aim: The aim of this study was to perform a cross-reactivity investigation of six benzofurans with immunoassays (IAs) screening tests for amphetamines and ecstasy in urine samples. Methods: The following benzofuranes were investigated: 5-(2-Methylaminopropyl)Benzofuran (5-MAPB), 5-(2-methylaminopropyl)-2,3-dihydrobenzofuran (5-MAPDB), 5-(2-Aminopropyl)-Benzofuran (5-APB), 5-(2-Aminopropyl)-2,3-dihydrobenzofuran (5-APDB), 5-(2-Ethylaminopropyl)Benzofuran (5-EAPB) and 5-(2-Aminoethyl)-2,3-dihydrobenzofuran (5-AEDB). The study was performed with urine-free spiked samples and authentic urine samples using eight different IAs for amphetamines and ecstasy. Results: All evaluated benzofurans showed cross-reactivity in some of the IAs tested, except for 5-AEDB. Urine samples of an intoxication case involving 5-MAPB, 5-APB and 5-EAPB were also positives in the IAs tested. Conclusion: There is an important variability in the cross-reactivity of the IAs for amphetamine and ecstasy caused by benzofurans depending on the immunoassay employed and the tested compounds. © 2017 Future Science Ltd.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.