The aim of this study was to establish the cut-off point of ultrasound (US) B-lines number for detecting the presence of significant interstitial lung disease (ILD) in patients with systemic sclerosis (SSc) (SSc-ILD) in relation to high-resolution computed tomography (HRCT) findings.Consecutive SSc-ILD patients underwent chest HRCT, lung US (LUS), pulmonary function test, and clinical assessment. Exclusion criteria were represented by the presence of a coexisting congestive heart failure and a clinical history suggestive of lung or pleural diseases. HRCT images were scored for the presence of ILD by 2 readers, in accordance with the Warrick scoring system. US assessment was performed by a US skilled rheumatologist, blinded to HRCT results and clinical data, and included the bilateral evaluation of 14 lung intercostal spaces (LIS). In each LIS, the number of B-lines was recorded and summed. To test discriminant validity, we used the receiver operating characteristic (ROC) curve analysis applying a Warrick score of 7 as external criterion for the presence of SSc-ILD.Forty patients completed the study. The US B-lines number and the Warrick score confirmed excellent correlation (Spearman rho: 0.958, P = .0001). The ROC curve analysis revealed that the presence of 10 US B-lines is the cut-off point with the greatest positive likelihood ratio (12.52) for the presence of significant SSc-ILD.The detection of 10 B-lines is highly predictive for the HRCT presence of significant SSc-ILD. In SSc patients, the LUS assessment as first imaging tool may represent an effective model to improve the correct timing of chest HRCT.

Ultrasound B-lines in the evaluation of interstitial lung disease in patients with systemic sclerosis: Cut-off point definition for the presence of significant pulmonary fibrosis / Tardella, Marika; DI CARLO, Marco; Carotti, Marina; Filippucci, Emilio; Grassi, Walter; Salaffi, Fausto. - In: MEDICINE. - ISSN 0025-7974. - STAMPA. - 97:18(2018). [10.1097/MD.0000000000010566]

Ultrasound B-lines in the evaluation of interstitial lung disease in patients with systemic sclerosis: Cut-off point definition for the presence of significant pulmonary fibrosis

Tardella Marika;Di Carlo Marco
;
Carotti Marina;Filippucci Emilio;Grassi Walter;Salaffi Fausto
2018-01-01

Abstract

The aim of this study was to establish the cut-off point of ultrasound (US) B-lines number for detecting the presence of significant interstitial lung disease (ILD) in patients with systemic sclerosis (SSc) (SSc-ILD) in relation to high-resolution computed tomography (HRCT) findings.Consecutive SSc-ILD patients underwent chest HRCT, lung US (LUS), pulmonary function test, and clinical assessment. Exclusion criteria were represented by the presence of a coexisting congestive heart failure and a clinical history suggestive of lung or pleural diseases. HRCT images were scored for the presence of ILD by 2 readers, in accordance with the Warrick scoring system. US assessment was performed by a US skilled rheumatologist, blinded to HRCT results and clinical data, and included the bilateral evaluation of 14 lung intercostal spaces (LIS). In each LIS, the number of B-lines was recorded and summed. To test discriminant validity, we used the receiver operating characteristic (ROC) curve analysis applying a Warrick score of 7 as external criterion for the presence of SSc-ILD.Forty patients completed the study. The US B-lines number and the Warrick score confirmed excellent correlation (Spearman rho: 0.958, P = .0001). The ROC curve analysis revealed that the presence of 10 US B-lines is the cut-off point with the greatest positive likelihood ratio (12.52) for the presence of significant SSc-ILD.The detection of 10 B-lines is highly predictive for the HRCT presence of significant SSc-ILD. In SSc patients, the LUS assessment as first imaging tool may represent an effective model to improve the correct timing of chest HRCT.
2018
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/258593
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 62
  • ???jsp.display-item.citation.isi??? 50
social impact