The paper deals with the evaluation of the effect of on/off switching of diffuser membranes, in the intermittent aeration process of the urban wastewater treatments. Accelerated tests were done using two types of commercial EPDM diffusers, which were submitted to several consecutive cycles up to the simulation of more than 8 years of real working conditions. The effect of this switching on the mechanical characteristics of the membranes was evaluated in terms of pressure increment of the air operating at different flow rates (2, 3.5 and 6 m3/h/diff): during accelerated tests, such increment ranged from 2% to 18%. The intermittent phases emphasized the loss both of the original mechanical proprieties of the diffusers and of the initial pore shapes. The main cause of pressure increment was attributed to the fouling of the internal channels of the pores. Further analyses performed by scanning electron microscopy and by mechanical tests on EPDM membrane, using a traditional tensile test and a non destructive optical method, from which the Young's Modulus was obtained, supported previous conclusions. Any changes in terms of oxygen transfer parameters (KLa and SOTE%) were specifically founded by causing to the repeated on/off switching.
Influence of aeration cycles on mechanical characteristics of elastomeric diffusers in biological intermittent processes: Accelerated tests in real environment / Eusebi, ANNA LAURA; Bellezze, Tiziano; Chiappini, Gianluca; Sasso, Marco; Battistoni, Paolo. - In: WATER RESEARCH. - ISSN 0043-1354. - ELETTRONICO. - 117:(2017), pp. 143-156. [10.1016/j.watres.2017.02.055]
Influence of aeration cycles on mechanical characteristics of elastomeric diffusers in biological intermittent processes: Accelerated tests in real environment
EUSEBI, ANNA LAURA
Investigation
;BELLEZZE, TizianoInvestigation
;CHIAPPINI, GIANLUCAInvestigation
;SASSO, MarcoSupervision
;BATTISTONI, PaoloFunding Acquisition
2017-01-01
Abstract
The paper deals with the evaluation of the effect of on/off switching of diffuser membranes, in the intermittent aeration process of the urban wastewater treatments. Accelerated tests were done using two types of commercial EPDM diffusers, which were submitted to several consecutive cycles up to the simulation of more than 8 years of real working conditions. The effect of this switching on the mechanical characteristics of the membranes was evaluated in terms of pressure increment of the air operating at different flow rates (2, 3.5 and 6 m3/h/diff): during accelerated tests, such increment ranged from 2% to 18%. The intermittent phases emphasized the loss both of the original mechanical proprieties of the diffusers and of the initial pore shapes. The main cause of pressure increment was attributed to the fouling of the internal channels of the pores. Further analyses performed by scanning electron microscopy and by mechanical tests on EPDM membrane, using a traditional tensile test and a non destructive optical method, from which the Young's Modulus was obtained, supported previous conclusions. Any changes in terms of oxygen transfer parameters (KLa and SOTE%) were specifically founded by causing to the repeated on/off switching.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.