The assessment of the state of conservation and risk of historical buildings represents a current and more and more important challenge. It usually requires different steps and is traditionally a cost, time-demanding and often unsafe process. This way, in this paper, a fast, low cost and safe methodology from 3D-laser scanner is provided for this issue. Following it, it is possible to easily assess if some activated mechanisms can be found in some macro-elements of the historical building. Furthermore, from the superposition of photographic data previous interventions can be recognized, as well as, degraded areas. This method was applied to the case study of Santa Maria in Portonovo church, a little jewel of the Italian Marche Romanesque architecture, where quite evident mechanisms were found in the face of the vestibule, in the north side wall, in the main facade and in the original apse. It was also possible to assess the typical physiologic deformation of the inner vaults subject to their own weight. A high number of areas largely restored by previous works were then found, probably due to a diffused and continuous degradation of the materials caused by the sea exposure. This method works well especially after, i.e. an earthquake, whereas it is possible to accurately evaluate the building safety far from it.

Fast, low cost and safe methodology for the assessment of the state of conservation of historical buildings from 3D laser scanning: The case study of Santa Maria in Portonovo (Italy) / Quagliarini, Enrico; Clini, Paolo; Ripanti, Mirko. - In: JOURNAL OF CULTURAL HERITAGE. - ISSN 1296-2074. - ELETTRONICO. - 24:C(2017), pp. 175-183. [10.1016/j.culher.2016.10.006]

Fast, low cost and safe methodology for the assessment of the state of conservation of historical buildings from 3D laser scanning: The case study of Santa Maria in Portonovo (Italy)

QUAGLIARINI, ENRICO
;
CLINI, Paolo;
2017-01-01

Abstract

The assessment of the state of conservation and risk of historical buildings represents a current and more and more important challenge. It usually requires different steps and is traditionally a cost, time-demanding and often unsafe process. This way, in this paper, a fast, low cost and safe methodology from 3D-laser scanner is provided for this issue. Following it, it is possible to easily assess if some activated mechanisms can be found in some macro-elements of the historical building. Furthermore, from the superposition of photographic data previous interventions can be recognized, as well as, degraded areas. This method was applied to the case study of Santa Maria in Portonovo church, a little jewel of the Italian Marche Romanesque architecture, where quite evident mechanisms were found in the face of the vestibule, in the north side wall, in the main facade and in the original apse. It was also possible to assess the typical physiologic deformation of the inner vaults subject to their own weight. A high number of areas largely restored by previous works were then found, probably due to a diffused and continuous degradation of the materials caused by the sea exposure. This method works well especially after, i.e. an earthquake, whereas it is possible to accurately evaluate the building safety far from it.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/245704
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 42
social impact