Recent decades have witnessed a growing attention to the indoor air quality issue. According to statistics, tipically indoor air quality is dramatically low due to several factors such as: the energy saving and the consequent decrease of ventilation, new building materials and new indoor pollution sources, as well as a frequent presence of cigarette smoke. Energy saving campaigns, combined with high energy prices, have pushed many people to make their homes hermetic as much as possible, reducing the air ventilation rate; it means that the quantity of outside air supplied by the infiltration through casing and fixtures is no longer sufficient to provide the necessary air exchange. Nowadays, in order to assess the minimun ventilation rate, there are several standards and guidelines, based on various parameters; however, it is still necessary a better knowledge of indoor air quality requirements rested on wellness goals, comfort and performance energy and all sources’ emission rates. This project aims at using an extended model for CO2 decay as a diagnostic tool to assess air infiltration rate in a building; an alternative method to the standard procedures, provided from the current state of the art, is suggested for an accurate building envelope classification. Such a method results to be more efficient from a logistic and economic point of view, of easy application, nevertheless able to maintain a high target accuracy.
Negli ultimi decenni si è assistito ad una crescente attenzione verso il tema della qualità dell’aria indoor. Infatti essa è diminuita drasticamente a causa di diversi fattori quali: il risparmio energetico e la conseguente diminuzione della ventilazione, nuovi materiali da costruzione e nuove fonti di inquinamento indoor, oltre ad una presenza frequente di fumo di sigaretta. Le numerose campagne di risparmio energetico, unite agli elevati prezzi dell'energia, hanno spinto molte persone a rendere il più possibile ermetiche le loro abitazioni riducendo anche il tasso di ventilazione; ciò significa che la quantità di aria esterna fornita dalle infiltrazioni attraverso l’involucro e gli infissi non è più sufficiente a fornire il necessario ricambio d’aria. Anche se ad oggi sono disponibili numerosi standard e linee guida per la valutazione del tasso di ventilazione minimo in base a vari parametri, c’è comunque la necessità di conoscere i requisiti di accettabilità dell'aria interna in base agli obiettivi di benessere, comfort e prestazioni energetiche e i tassi di emissione da tutte le fonti. L’idea del progetto è di utilizzare un modello esteso per il decadimento della CO2 come strumento di diagnosi delle infiltrazioni all’aria di un edificio, ai fini della classificazione dell’involucro edilizio; si propone una metodologia alternativa alle procedure standard per il calcolo della tenuta all’aria, previste dall’attuale stato dell’arte, che risulti più efficiente da un punto di vista logistico ed economico, di facile applicazione, in grado di mantenere comunque un elevato target di accuratezza.
modellazione del decadimento indoor della concentrazione di co2 per la determinazione della permeabilità all’aria dell’involucro edilizio / Pascucci, Michele. - (2017 Mar 02).
modellazione del decadimento indoor della concentrazione di co2 per la determinazione della permeabilità all’aria dell’involucro edilizio
PASCUCCI, MICHELE
2017-03-02
Abstract
Recent decades have witnessed a growing attention to the indoor air quality issue. According to statistics, tipically indoor air quality is dramatically low due to several factors such as: the energy saving and the consequent decrease of ventilation, new building materials and new indoor pollution sources, as well as a frequent presence of cigarette smoke. Energy saving campaigns, combined with high energy prices, have pushed many people to make their homes hermetic as much as possible, reducing the air ventilation rate; it means that the quantity of outside air supplied by the infiltration through casing and fixtures is no longer sufficient to provide the necessary air exchange. Nowadays, in order to assess the minimun ventilation rate, there are several standards and guidelines, based on various parameters; however, it is still necessary a better knowledge of indoor air quality requirements rested on wellness goals, comfort and performance energy and all sources’ emission rates. This project aims at using an extended model for CO2 decay as a diagnostic tool to assess air infiltration rate in a building; an alternative method to the standard procedures, provided from the current state of the art, is suggested for an accurate building envelope classification. Such a method results to be more efficient from a logistic and economic point of view, of easy application, nevertheless able to maintain a high target accuracy.File | Dimensione | Formato | |
---|---|---|---|
tesi_pascucci.pdf
accesso aperto
Descrizione: tesi_pascucci
Tipologia:
Tesi di dottorato
Licenza d'uso:
Tutti i diritti riservati
Dimensione
5.64 MB
Formato
Adobe PDF
|
5.64 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.