This manuscript reports the structural alterations occurring in mice skeleton as a consequence of the longest-term exposition (90 days) to simulated microgravity (hindlimb unloading) and hypergravity (2g) ever tested. Bone microstructural features were investigated by means of standard Cone Beam X-Ray micro-CT, Synchrotron Radiation micro-CT and histology. Morphometric analysis confirmed deleterious bone architectural changes in lack of mechanical loading with a decrease of bone volume and density, while bone structure alterations caused by hypergravity were less evident. In the femurs from hypergravity-exposed mice, the head/neck cortical thickness increment was the main finding. In addition, in these mice the rate of larger trabeculae (60-75 μm) was significantly increased. Interestingly, the metaphyseal plate presented a significant adaptation to gravity changes. Mineralization of cartilage and bone deposition was increased in the 2g mice, whereas an enlargement of the growth plate cartilage was observed in the hindlimb unloaded group. Indeed, the presented data confirm and reinforce the detrimental effects on bone observed in real space microgravity and reveal region-specific effects on long bones. Finally these data could represent the starting point for further long-term experimentations that can deeply investigate the bone adaptation mechanisms to different mechanical force environments.

Effects of long time exposure to simulated micro- and hypergravity on skeletal architecture / Canciani, Barbara; Ruggiu, Alessandra; Giuliani, Alessandra; Panetta, Daniele; Marozzi, Katia; Tripodi, Maria; Salvadori, Piero A; Cilli, Michele; Ohira, Yoshinobu; Cancedda, Ranieri; Tavella, Sara. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - ELETTRONICO. - 51:(2015), pp. 1-12. [10.1016/j.jmbbm.2015.06.014]

Effects of long time exposure to simulated micro- and hypergravity on skeletal architecture

GIULIANI, ALESSANDRA
Formal Analysis
;
MAROZZI, KATIA
Investigation
;
2015-01-01

Abstract

This manuscript reports the structural alterations occurring in mice skeleton as a consequence of the longest-term exposition (90 days) to simulated microgravity (hindlimb unloading) and hypergravity (2g) ever tested. Bone microstructural features were investigated by means of standard Cone Beam X-Ray micro-CT, Synchrotron Radiation micro-CT and histology. Morphometric analysis confirmed deleterious bone architectural changes in lack of mechanical loading with a decrease of bone volume and density, while bone structure alterations caused by hypergravity were less evident. In the femurs from hypergravity-exposed mice, the head/neck cortical thickness increment was the main finding. In addition, in these mice the rate of larger trabeculae (60-75 μm) was significantly increased. Interestingly, the metaphyseal plate presented a significant adaptation to gravity changes. Mineralization of cartilage and bone deposition was increased in the 2g mice, whereas an enlargement of the growth plate cartilage was observed in the hindlimb unloaded group. Indeed, the presented data confirm and reinforce the detrimental effects on bone observed in real space microgravity and reveal region-specific effects on long bones. Finally these data could represent the starting point for further long-term experimentations that can deeply investigate the bone adaptation mechanisms to different mechanical force environments.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/227294
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? 23
social impact