To date, a large part of workers is exposed to vibrations (23% in Europe) which can negatively impact on their health. This work discusses the importance of measuring grip and push forces in the context of hand-arm vibration tests, bearing in mind the state-of-art of current standards. It proposes a method for indirect measurement of coupling forces using a matrix of polymeric pressure capacitive sensors and discusses the model used for defining these quantities. The matrix of pressure sensors is wrapped around the tool handle and the acting forces, exchanged with the handle, are derived from the pressure values measured by the matrix. Calibration is presented and the effect of curvature is discussed. The work continues with the experimental validation of the model proposed for push force measurements carried out through lifting tests using known masses with a cylindrical handle. An experimental correction coefficient is defined in correlation to the type of grip. The method for measuring the push force, thus corrected, is assessed by means of push force tests on an instrumented handle. Finally the experimental data are analysed in order to assess the uncertainty of the proposed method for measuring the push force, highlighting the contribution of the different sources of uncertainty. The proposed measurement method allows to measure the push and the grip force (known influencing quantities for the measurement of the hand-arm vibration) during tool test and without modifying the handles.
Pressure Sensor Matrix for Indirect Measurement of Grip and Push Forces Exerted on a Handle / Scalise, Lorenzo; Paone, Nicola. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 73:(2015), pp. 419-428. [10.1016/j.measurement.2015.05.044]
Pressure Sensor Matrix for Indirect Measurement of Grip and Push Forces Exerted on a Handle
SCALISE, Lorenzo;PAONE, Nicola
2015-01-01
Abstract
To date, a large part of workers is exposed to vibrations (23% in Europe) which can negatively impact on their health. This work discusses the importance of measuring grip and push forces in the context of hand-arm vibration tests, bearing in mind the state-of-art of current standards. It proposes a method for indirect measurement of coupling forces using a matrix of polymeric pressure capacitive sensors and discusses the model used for defining these quantities. The matrix of pressure sensors is wrapped around the tool handle and the acting forces, exchanged with the handle, are derived from the pressure values measured by the matrix. Calibration is presented and the effect of curvature is discussed. The work continues with the experimental validation of the model proposed for push force measurements carried out through lifting tests using known masses with a cylindrical handle. An experimental correction coefficient is defined in correlation to the type of grip. The method for measuring the push force, thus corrected, is assessed by means of push force tests on an instrumented handle. Finally the experimental data are analysed in order to assess the uncertainty of the proposed method for measuring the push force, highlighting the contribution of the different sources of uncertainty. The proposed measurement method allows to measure the push and the grip force (known influencing quantities for the measurement of the hand-arm vibration) during tool test and without modifying the handles.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.