A proper recognition of the pollutant sources in atmospheric deposit is a key problem for any action aiming at reducing their emission, being this an important issue with implications both on human health safeguard and on the cultural heritage conservation in urban sites. Thiswork presents the results of a statistical approach application for the identification of pollutant sources in deposits and damage layers onmonuments located in different European sites: Santa Maria del Fiore, Florence (Italy), Cologne Cathedral, Cologne (Germany), Ancient ramparts, Salè (Morocco), National Museum, Cracow (Poland) and National Gallery, Oslo (Norway). For this aim, the surface damage layers on monuments and historical buildings of the selected sites were collected and analyzed, in terms of ionic and elemental composition, through application of ion chromatography and induced coupled plasma-opticalemission spectroscopy. The achieved results were processed bymultivariate analyses such as correlation matrix and principal component analysis in order to identify the possible origin of pollutants affecting the state of conservation of the monuments. This allowed us to assume that in all case studies the traffic emission is the main pollutant source. In the case of Ancient ramparts, Salè (Morocco), and National Gallery, Oslo (Norway), the surfaces are also under influence of marine aerosols. Moreover, concerning the Cologne Cathedral, the strong impact of the pollutants emitted by railway station was also revealed.

Assessment of air pollutant sources in the deposit on monuments by multivariate analysis / Izabela, Ozga; Nadia, Ghedini; Giosue', Chiara; Cristina, Sabbioni; Tittarelli, Francesca; Alessandra, Bonazza. - In: SCIENCE OF THE TOTAL ENVIRONMENT. - ISSN 0048-9697. - STAMPA. - 490:(2014), pp. 776-784. [10.1016/j.scitotenv.2014.05.084]

Assessment of air pollutant sources in the deposit on monuments by multivariate analysis

GIOSUE', CHIARA;TITTARELLI, Francesca;
2014-01-01

Abstract

A proper recognition of the pollutant sources in atmospheric deposit is a key problem for any action aiming at reducing their emission, being this an important issue with implications both on human health safeguard and on the cultural heritage conservation in urban sites. Thiswork presents the results of a statistical approach application for the identification of pollutant sources in deposits and damage layers onmonuments located in different European sites: Santa Maria del Fiore, Florence (Italy), Cologne Cathedral, Cologne (Germany), Ancient ramparts, Salè (Morocco), National Museum, Cracow (Poland) and National Gallery, Oslo (Norway). For this aim, the surface damage layers on monuments and historical buildings of the selected sites were collected and analyzed, in terms of ionic and elemental composition, through application of ion chromatography and induced coupled plasma-opticalemission spectroscopy. The achieved results were processed bymultivariate analyses such as correlation matrix and principal component analysis in order to identify the possible origin of pollutants affecting the state of conservation of the monuments. This allowed us to assume that in all case studies the traffic emission is the main pollutant source. In the case of Ancient ramparts, Salè (Morocco), and National Gallery, Oslo (Norway), the surfaces are also under influence of marine aerosols. Moreover, concerning the Cologne Cathedral, the strong impact of the pollutants emitted by railway station was also revealed.
2014
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/172509
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 48
  • ???jsp.display-item.citation.isi??? 41
social impact