For the first time, square-wave anodic-stripping voltammetry (SWASV) was set up and optimized for the determination of Cd, Pb and Cu in white wine after UV photo-oxidative digestion of the sample. The best procedure for the sample pre-treatment consisted in a 6-h UV irradiation of diluted, acidified wine, with the addition of ultrapure H2O2 (three sequential additions during the irradiation). Due to metal concentration differences, separate measurements were carried out for Cd (deposition potential −950 mV vs. Ag/AgCl/3 M KCl deposition time 15 min) and simultaneously for Pb and Cu (Ed −750 mV, td 30 s). The optimum set-up of the main instrumental parameters, evaluated also in terms of the signalto- noise ratio, were as follows: ESW 20 mV, f 100 Hz, Estep 8 mV, tstep 100 ms, twait 60 ms, tdelay 2 ms, tmeas 3 ms. The electrochemical behaviour was reversible bielectronic for Cd and Pb, and kinetically controlled monoelectronic for Cu. Good accuracy was found both when the recovery procedure was used and when the results were compared with data obtained by differential pulse anodic stripping voltammetry. The linearity of the response was verified up to∼4 g L−1 for Cd and Pb and∼15 g L−1 for Cu. The detection limits for td = 5 min in the 10 times diluted, UV digested sample were (ng L−1): Cd 7.0, Pb 1.2 nd Cu 6.6, which are well below currently applied methods. Application to a Verdicchio dei Castelli di Jesi white wine revealed concentration levels of Cd ∼0.2, Pb∼10, Cu∼30 g L−1 with repeatabilities of (±RSD%) Cd±6%,Pb±5%, Cu±10%.

Square-wave anodic-stripping voltammetric determination of Cd, Pb and Cu in wine: Set-up and optimization of sample pre-treatment and instrumental parameters / Illuminati, Silvia; Annibaldi, Anna; Truzzi, Cristina; Finale, Carolina; Scarponi, Giuseppe. - In: ELECTROCHIMICA ACTA. - ISSN 0013-4686. - STAMPA. - 104:(2013), pp. 148-161.

Square-wave anodic-stripping voltammetric determination of Cd, Pb and Cu in wine: Set-up and optimization of sample pre-treatment and instrumental parameters

ILLUMINATI, Silvia;ANNIBALDI, ANNA;TRUZZI, Cristina;FINALE, CAROLINA;SCARPONI, Giuseppe
2013-01-01

Abstract

For the first time, square-wave anodic-stripping voltammetry (SWASV) was set up and optimized for the determination of Cd, Pb and Cu in white wine after UV photo-oxidative digestion of the sample. The best procedure for the sample pre-treatment consisted in a 6-h UV irradiation of diluted, acidified wine, with the addition of ultrapure H2O2 (three sequential additions during the irradiation). Due to metal concentration differences, separate measurements were carried out for Cd (deposition potential −950 mV vs. Ag/AgCl/3 M KCl deposition time 15 min) and simultaneously for Pb and Cu (Ed −750 mV, td 30 s). The optimum set-up of the main instrumental parameters, evaluated also in terms of the signalto- noise ratio, were as follows: ESW 20 mV, f 100 Hz, Estep 8 mV, tstep 100 ms, twait 60 ms, tdelay 2 ms, tmeas 3 ms. The electrochemical behaviour was reversible bielectronic for Cd and Pb, and kinetically controlled monoelectronic for Cu. Good accuracy was found both when the recovery procedure was used and when the results were compared with data obtained by differential pulse anodic stripping voltammetry. The linearity of the response was verified up to∼4 g L−1 for Cd and Pb and∼15 g L−1 for Cu. The detection limits for td = 5 min in the 10 times diluted, UV digested sample were (ng L−1): Cd 7.0, Pb 1.2 nd Cu 6.6, which are well below currently applied methods. Application to a Verdicchio dei Castelli di Jesi white wine revealed concentration levels of Cd ∼0.2, Pb∼10, Cu∼30 g L−1 with repeatabilities of (±RSD%) Cd±6%,Pb±5%, Cu±10%.
2013
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/144295
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 29
social impact