In this paper we demonstrate a general multimodal calibration technique allowing the experimental characterization of overmoded waveguides and waveguide devices. The proposed technique produces a measured Generalized Scattering Matrix, and proves to be robust and accurate, as demonstrated by the excellent agreement between measured and analytical data for a set of empty waveguides. As a byproduct, the technique allows the measurement of the propagation constant of waveguides having arbitrary cross-sections.
A Multimodal Calibration Technique for Waveguide Devices / Morini, Antonio; Guglielmi, M.; Farina, Marco. - ELETTRONICO. - (2012), pp. 597-600. (Intervento presentato al convegno European Microwave Conference tenutosi a Amsterdam nel 29 Oct.-1Nov. 2012).
A Multimodal Calibration Technique for Waveguide Devices
MORINI, ANTONIO;FARINA, Marco
2012-01-01
Abstract
In this paper we demonstrate a general multimodal calibration technique allowing the experimental characterization of overmoded waveguides and waveguide devices. The proposed technique produces a measured Generalized Scattering Matrix, and proves to be robust and accurate, as demonstrated by the excellent agreement between measured and analytical data for a set of empty waveguides. As a byproduct, the technique allows the measurement of the propagation constant of waveguides having arbitrary cross-sections.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.