In this paper an optimization of the set-up for the shielding effectiveness measurement of a closed thin enclosure is shown. Various sort of noise, due to the measuring set-up, can superimpose to the signal of interest, making difficult to recover it from what is received by the instruments. A complete analysis of the problems that arise in the case of ESD, CW conducted and CW radiated excitations is presented, together with their solutions.
Measurement system for thin shield effectiveness / Aiello, A; MARIANI PRIMIANI, Valter; Righetti, M; Tribellini, G.. - 3:(1996), pp. 1379-1382. (Intervento presentato al convegno Mediterranean Electrotechnical Conference - MELECON 96 tenutosi a Bari, Italy nel 1996).
Measurement system for thin shield effectiveness
MARIANI PRIMIANI, Valter;
1996-01-01
Abstract
In this paper an optimization of the set-up for the shielding effectiveness measurement of a closed thin enclosure is shown. Various sort of noise, due to the measuring set-up, can superimpose to the signal of interest, making difficult to recover it from what is received by the instruments. A complete analysis of the problems that arise in the case of ESD, CW conducted and CW radiated excitations is presented, together with their solutions.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.