The measurement of concentration of blood gases (in particular O2) is of extreme interest for the evaluation of efficiency of pulmonary gas exchange, adequacy of alveolar ventilation, mechanisms of blood-gas transport and tissue oxygenation. Invasive techniques, although still common in many clinical situations, present the limit to be necessary not continuous, time-delayed (typically 20-30 min), painful and with an associated risk. Such limitation becomes particularly severe in critical ill patients where close and frequent (continuous) monitoring of arterial blood gases is essential. In this paper, we describe a real-time, novel measurement procedure to validate non-invasive arterial oxygen saturation (SO2) data measured by standard pulse-oxymeter. Such instrument, especially when used in intensive care units (ICU), can produce wrong data due to voluntary or involuntary motion artefacts or imperfect skin-sensor contact. We have monitored (sampling frequency: 1 Hz) in 14 preterm subjects and used the heart rate (HR) signal provided by the ECG (II-lead) and the same quantity provided by the SO2 sensor (SHR); such data have been used to validate the SO2 data. A dedicated algorithm has been developed in order to provided “most-probable” values in case of single or few not validated SO2 data. Results show that less than 10% of the arterial oxygen saturation data are not validated, which means, in our case, 25 hours of data (out of 250 hours observed) are not validated. With the provided algorithm the still not validated data are reduced to less than 5%.

A non contact, optical procedure for precise measurement of respiration rate and flow / Scalise, Lorenzo; P., Marchionni; I., Ercoli. - 7715/2010:(2010), pp. 77150G1-77150G8. (Intervento presentato al convegno SPIE Photonics Europe tenutosi a Brussels, Belgium nel 12-16 April 2010) [10.1117/12.854482].

A non contact, optical procedure for precise measurement of respiration rate and flow.

SCALISE, Lorenzo;
2010-01-01

Abstract

The measurement of concentration of blood gases (in particular O2) is of extreme interest for the evaluation of efficiency of pulmonary gas exchange, adequacy of alveolar ventilation, mechanisms of blood-gas transport and tissue oxygenation. Invasive techniques, although still common in many clinical situations, present the limit to be necessary not continuous, time-delayed (typically 20-30 min), painful and with an associated risk. Such limitation becomes particularly severe in critical ill patients where close and frequent (continuous) monitoring of arterial blood gases is essential. In this paper, we describe a real-time, novel measurement procedure to validate non-invasive arterial oxygen saturation (SO2) data measured by standard pulse-oxymeter. Such instrument, especially when used in intensive care units (ICU), can produce wrong data due to voluntary or involuntary motion artefacts or imperfect skin-sensor contact. We have monitored (sampling frequency: 1 Hz) in 14 preterm subjects and used the heart rate (HR) signal provided by the ECG (II-lead) and the same quantity provided by the SO2 sensor (SHR); such data have been used to validate the SO2 data. A dedicated algorithm has been developed in order to provided “most-probable” values in case of single or few not validated SO2 data. Results show that less than 10% of the arterial oxygen saturation data are not validated, which means, in our case, 25 hours of data (out of 250 hours observed) are not validated. With the provided algorithm the still not validated data are reduced to less than 5%.
2010
9780819481887
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11566/62541
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 6
social impact